Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 16 OF 161

OLS Field Name OLS Field Data
Main Title Background document on proposed liner and leak detection rule / prepared for U.S. Environmental Protection Agency by GeoServices Inc. Consulting Engineers.
Author Bonaparte, R. ; Giroud, J. P. ; Wallace, R. B. ; Ah-Line, C. ; Prillman, J.
CORP Author NUS Corp., Rockville, MD. ;GeoServices, Inc., Boynton Beach, FL.;Environmental Protection Agency, Washington, DC. Office of Solid Waste.
Publisher U.S. Environmental Protection Agency, Office of Solid Waste,
Year Published 1987
Report Number EPA/530-SW-87-015; EPA-68-01-7310
Stock Number PB87-191383
OCLC Number 17983979
Subjects Sanitary landfills--Linings.
Additional Subjects Waste disposal ; Leakage ; Hazardous materials ; Seepage ; Leak detectors ; Linings ; Quality assurance ; Performance ; Earth fills ; Regulations ; Containment ; Liner Leak Detection Rules ; Solid wastes ; Waste management
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=20012C5Z.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD ARCHIVE EPA 530-SW-87-015 pt. 1 Headquarters Library/Washington,DC 03/20/2014
EJBD ARCHIVE EPA 530-SW-87-015 pt. 2 Headquarters Library/Washington,DC 03/20/2014
EJBD  EPA 530-SW-87-015 pt. 1 c.1 Headquarters Library/Washington,DC 03/20/2014
EJBD  EPA 530-SW-87-015 pt. 2 c.1 Headquarters Library/Washington,DC 03/20/2014
NTIS  PB87-191383 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation 1 v. (various pagings) ; 28cm.
Abstract The document presents a state-of-the-art review of available technologies and achievable performance levels in leak detection systems at hazardous waste management units. The review is necessary to establish the best demonstrated available technology (BDAT) for leak detection systems. It provides the critical information considered in developing EPA's regulatory options and describes the criteria used to select among the options. The document also presents a rationale and technical data to support extension of the double-liner system requirements to waste piles, significant unused portions, and certain other units. Lastly, the document presents a comprehensive discussion of the issues, methodologies, and benefits associated with construction quality assurance programs at hazardous waste management facilities.
Notes "May 1987." "Prepared for U.S. Environmental Protection Agency, Office of Solid Waste under NUS Corporation contract no. 68-01-7310 work assignment no. 7 (amendment 3) by GeoServices Inc. Consulting Engineers."
Place Published Washington, D.C.
Supplementary Notes Portions of this document are not fully legible. Prepared in cooperation with GeoServices, Inc., Boynton Beach, FL. Sponsored by Environmental Protection Agency, Washington, DC. Office of Solid Waste.
Access Notes Also available via the World Wide Web.
Corporate Au Added Ent United States. Office of Solid Waste.; Geoservices.
Alternate Title Proposed liner and leak detection rule
PUB Date Free Form 1987
Ti Tra Differently Proposed liner and leak detection rule.
NTIS Prices PC A23/MF A01
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20111003165654
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01329cam 2200301Ka 45020