Grantee Research Project Results
2003 Progress Report: Source Apportionment of Indoor PAHs in Urban Residences 98-03B
EPA Grant Number: R828678C008Subproject: this is subproject number 008 , established and managed by the Center Director under grant R824834
(EPA does not fund or establish subprojects; EPA awards and manages the overall grant for this center).
Center: Center for Integrating Statistical and Environmental Science
Center Director: Stein, Michael
Title: Source Apportionment of Indoor PAHs in Urban Residences 98-03B
Investigators: Li, An
Institution: University of Illinois at Chicago
EPA Project Officer: Chung, Serena
Project Period: January 2, 2001 through December 31, 2005 (Extended to December 31, 2008)
Project Period Covered by this Report: January 2, 2003 through December 31, 2004
RFA: Mickey Leland National Urban Air Toxics Research Center (NUATRC) (1997) RFA Text | Recipients Lists
Research Category: Air Quality and Air Toxics , Targeted Research
Objective:
The overall objective of this project was to measure the concentrations of 16 selected polycyclic aromatic hydrocarbons (PAHs) in the indoor and outdoor environment of 10 homes in a residential area of south Chicago once a month for one year. Using these measurements and using different models, the investigator would determine the source for these PAHs as coming from indoor or outdoor sources. Because PAHs are toxic (development of lung and skin cancers, GI, urologic, laryngeal and pharyngeal malignancies and enhanced immune or allergic responses), identification of the concentrations of PAHs in an indoor environment as well as accurate source apportionment of the contributions from indoor and outdoor sources would be helpful in designing strategies for reduction of these exposures.
The specific objectives of the study were: (1) assess relative contributions from outdoor sources to indoor PAHs in urban homes; (2) identify major sources and estimate emission rates; and (3) examine factors that control/modify indoor PAH concentrations.
Progress Summary:
This research was funded by the Mickey Leland National Urban Air Toxics Research Center (NUATRC) under its small grants New Investigators Award. The two year project began in August 1999 (under Grant No. R824834C008). The project is in compliance with the University of Illinois Institutional Review Board for use of human subject protocols and human consent regulations. The project is also in compliance with appropriate quality control and quality assurance procedures and per guidelines of NUATRC and the U.S. Environmental Protection Agency (EPA).
NUATRC received a draft Final Report for the study in March 2002. The report was reviewed by a team of external peer-reviewers and the NUATRC Scientific Advisory Panel (SAP). The NUATRC received Dr. Li’s Revised Final Report in April 2003, which was reviewed by the SAP. A second Revised Final Report was received in December 2003. The report is currently undergoing scientific editing. The study has been granted a no-cost extension through August 2004 in order to complete scientific editing and publication.
Ten homes in the Chicago area participated in this study on a voluntary basis. They were selected based on the response to a household screening survey questionnaire. Indoor and outdoor air samples at these homes were concurrently collected once a month for a 14-month period. Each sampling lasted 46 hours at an airflow rate of about 10 liters per minute (Lpm). Real time monitoring and recording of the air quality (temperature, humidity, CO2) was carried out during each sample, both indoors and outdoors. Carbon monoxide concentration in indoor air was also recorded. During each sample, a home status questionnaire was taken to register the household activities and events which may affect the PAH levels.
The study resulted in the development of the programmable temperature vaporization technique (PTV) over large-volume injections for analyses with low concentrations of PAHs. For most PAHs, the response of the mass spectrometry detector increased proportionally as the total volume was increased up to 150 μL using the PTV. This is a significant improvement over existing methodologies.
The results of the study suggest that correlations between indoor and outdoor total PAHs are weak. In general, the results suggest that (1) PAHs are ubiquitously present in non-smoker urban homes and indoor PAH concentrations are affected largely by indoor activities; (2) outdoor air may also contribute significantly to indoor PAH levels, especially for the heavier compounds; (3) the partitioning of indoor PAHs between air, suspended particles, and settled particles (dust) needs to be investigated further; and (4) the indoor source emissions need to be quantitatively characterized, and relative source contributions be apportioned.
Future Activities:
- Scientific editing of the Revised Final Report.
- Publication of the report.
Journal Articles on this Report : 2 Displayed | Download in RIS Format
Other subproject views: | All 7 publications | 4 publications in selected types | All 3 journal articles |
---|---|---|---|
Other center views: | All 144 publications | 62 publications in selected types | All 53 journal articles |
Type | Citation | ||
---|---|---|---|
|
Li A, Schoonover TM, Zou Q, Norlock F, Conroy LM, Scheff PA, Wadden RA. Polycyclic aromatic hydrocarbons in residential air of ten Chicago area homes:concentrations and influencing factors. Atmospheric Environment 2005;39(19):3491-3501. |
R828678C008 (2003) R828678C008 (2004) R828678C008 (Final) |
Exit Exit Exit |
|
Norlock FM, Jang JK, Zou Q, Schoonover TM, Li A. Large-volume injection PTV-GC-MS analysis of polycyclic aromatic hydrocarbons in air and sediment samples. Journal of the Air & Waste Management Association 2002;52(1):19-26. |
R828678C008 (2003) R828678C008 (2004) R828678C008 (Final) |
Exit |
Supplemental Keywords:
RFA, Scientific Discipline, Health, Air, ENVIRONMENTAL MANAGEMENT, particulate matter, Air Pollution, air toxics, Environmental Chemistry, Health Risk Assessment, Risk Assessments, Atmospheric Sciences, Biology, Risk Assessment, copollutant exposures, atmospheric particulate matter, cardiopulmonary responses, fine particles, PM 2.5, air pollutants, acute lung injury, exposure, chronic health effects, lung inflammation, particulate exposure, PAHs, industrial air pollution, human exposure, Acute health effects, inhaled, indoor/outdoor relationships, atmospheric chemistry, airborne urban contaminants, acute exposure, human health riskRelevant Websites:
http://www.sph.uth.tmc.edu/mleland/ Exit
Progress and Final Reports:
Original AbstractMain Center Abstract and Reports:
R824834 Center for Integrating Statistical and Environmental Science Subprojects under this Center: (EPA does not fund or establish subprojects; EPA awards and manages the overall grant for this center).
R824834C001 Air Toxics Exposures Among Teenagers in New York City and Los Angeles - A Columbia-Harvard Study (TEACH)
R824834C002 Cardiopulmonary Response to Particulate Exposure
R824834C003 VOC Exposure in an Industry Impacted Community
R824834C004 A Study of Personal Exposure to Air Toxics Among a Subset of the Residential U.S. Population (VOC Project)
R824834C005 Methods Development Project for a Study of Personal Exposures to Toxic Air Pollutants
R824834C006 Relationship Between Indoor, Outdoor and Personal Air (RIOPA)
R824834C007 Development of the "Leland Legacy" Air Sampling Pump
R824834C008 Source Apportionment of Indoor Polycyclic Aromatic Hydrocarbons (PAHs) in Urban Residences
R824834C009 Development of a Personal Cascade Impactor Sampler (PCIS)
R824834C010 Testing the Metals Hypothesis in Spokane
R828678C001 Air Toxics Exposures Among Teenagers in New York City and Los Angeles—A Columbia-Harvard Study (TEACH)
R828678C002 Cardiopulmonary Effects of Metal-Containing Particulate Exposure
R828678C003 VOC Exposure in an Industry Impacted Community
R828678C004 A Study of Personal Exposure to Air Toxics Among a Subset of the Residential U.S. Population (VOC Project)
R828678C005 Oxygenated Urban Air Toxics and Asthma Variability in Middle School Children: A Panel Study (ATAC–Air Toxics and Asthma in Children)
R828678C006 Relationship between Indoor, Outdoor and Personal Air (RIOPA). Part II: Analyses of Concentrations of Particulate Matter Species
R828678C007 Development of the “Leland Legacy” Air Sampling Pump
R828678C008 Source Apportionment of Indoor PAHs in Urban Residences 98-03B
R828678C009 Development of a Personal Cascade Impactor Sampler (PCIS)
R828678C010 Testing the Metals Hypothesis in Spokane
R828678C011 A Pilot Geospatial Analysis of Exposure to Air Pollutants (with Special Attention to Air Toxics) and Hospital Admissions in Harris County, Texas
R828678C012 Impact of Exposure to Urban Air Toxics on Asthma Utilization for the Pediatric Medicaid Population in Dearborn, Michigan
R828678C013 Field Validation of the Sioutas Sampler and Leland Legacy Pump – Joint Project with EPA’s Environmental Technology Validation Program (ETV)
R828678C014 Performance Evaluation of the 3M Charcoal Vapor Monitor for Monitor Low Ambient Concentrations of VOCs
R828678C015 RIOPA Database Development
R828678C016 Contributions of Outdoor PM Sources to Indoor and Personal Exposures: Analysis of PM Species Concentrations” Focused on the PM Speciation and Apportioning of Sources
R828678C017 The Short and Long-Term Respiratory Effects of Exposure to PAHs from Traffic in a Cohort of Asthmatic Children
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Conclusions drawn by the principal investigators have not been reviewed by the Agency.
Project Research Results
- Final Report
- 2007
- 2006
- 2005
- 2004 Progress Report
- 2002 Progress Report
- 2001 Progress Report
- Original Abstract
3 journal articles for this subproject
Main Center: R824834
144 publications for this center
53 journal articles for this center