Main Title |
Field Evaluation of a Utility Dry Scrubbing System. |
Author |
Blythe, G. M. ;
Burke, J. M. ;
Lewis, D. L. ;
Thompson, C. M. ;
|
CORP Author |
Radian Corp., Austin, TX.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.;Electric Power Research Inst., Palo Alto, CA. |
Year Published |
1985 |
Report Number |
RAD-84-203-001-57-17; EPA-68-02-3171; EPA/600/7-85-020; |
Stock Number |
PB85-207488 |
Additional Subjects |
Air pollution control equipment ;
Scrubbers ;
Flue gases ;
Boilers ;
Combustion products ;
Industrial wastes ;
Performance evaluation ;
Calcium chlorides ;
Particles ;
Sulfuric acid ;
Particles ;
Field tests ;
Dry methods ;
Coal fired power plants ;
Spray dryers ;
Limestone scrubbing ;
Flue gas desulfurization ;
Waste utilization ;
Solid wastes
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB85-207488 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
329p |
Abstract |
The report gives results of the first independent evaluation of a full-scale utility spray-dryer/baghouse dry flue gas desulfurization (FGD) system. The system treats flue gas from a nominal 100 MW of coal-fired power generation. The test program, conducted during July-October 1983, used two different coals as boiler fuels: one, a subbituminous coal and coke mixture with a nominal 1.2 percent sulfur content; and the other, a 3.4 percent sulfur Illinois bituminous coal. SO2 removal, particulate emissions, sulfuric acid removal, and extensive process data were recorded. Low sulfur coal tests indicated that 75 percent SO2 removal was achievable in the short term at reagent ratios of 0.6 to 0.7, and 90 percent SO2 removal was achievable at a reagent ratio of about 0.8. An average removal of nearly 90 percent was achieved in short-term tests with high sulfur coal at reagent ratios of 1.3 to 1.4. Calcium chloride addition to the atomizer feed slurry was found to reduce the lime addition requirements for high sulfur tests by about 25 percent. |
Supplementary Notes |
Sponsored by Electric Power Research Inst., Palo Alto, CA. |
NTIS Title Notes |
Final rept. Apr 82-Nov 84. |
PUB Date Free Form |
May 85 |
Category Codes |
13B; 68A; 97R; 68C |
NTIS Prices |
PC A15/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
522820822 |
Origin |
NTIS |
Type |
CAT |