Main Title |
Airborne Monitoring of Cooling Tower Effluents. Volume I. Technical Summary. |
Author |
Woffinden, George J. ;
Harrison, Paul R. ;
Anderson., Jerry A. ;
|
CORP Author |
Meteorology Research, Inc., Altadena, Calif.;Corvallis Environmental Research Lab., Oreg.;Electric Power Research Inst., Palo Alto, Calif. |
Year Published |
1978 |
Report Number |
EPA-R-803969; EPRI-484; EPA/600/7-78/079 ; EPRI/EA-420 |
Stock Number |
PB-279 076 |
Additional Subjects |
Cooling towers ;
Air pollution ;
Plumes ;
Flue gases ;
Monitoring ;
Boilers ;
Sodium chloride ;
Sulfur dioxide ;
Sulfuric acid ;
Particle size distribution ;
Turbulence ;
Visibility ;
Concentration(Composition) ;
Precipitation(Meteorology) ;
Laboratory equipment ;
Water vapor ;
Aircraft ;
Temperature ;
Dew Point ;
Water ;
Air pollution detection ;
Air water interactions
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB-279 076 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
122p |
Abstract |
MRI conducted an airborne plume monitoring program as part of the Chalk Point Cooling Tower Project. Plume measurement included: temperature, dew point, visibility, turbulence, droplet size distribution and concentration, liquid water content, sodium chloride concentration (NaCl), sulfuric acid concentration (H2SO4), sulfur dioxide concentration (SO2). Vertical cross sections of the plume were mapped at several downwind distances. Data were recorded every half second to provide the short response times required for accurate plume profile measurements. The presence of stable visible plumes was observed during cold high humidity conditions. Even under these conditions, the decrease in visibility is not considered to be a hazard to aircraft because of the limited distance over which it extends. Interactions between the cooling tower plume and the boiler plume are limited. The boiler plume is saturated with water from combustion products and from a venturi wet scrubber. Therefore, chemical reactions that require moisture have occurred prior to mixing with the cooling tower plume, and the additional water supplied by the cooling tower plume has little effect. |
NTIS Title Notes |
Final rept.. |
PUB Date Free Form |
Apr 78 |
Category Codes |
13A; 7D; 68A; 99A; 94 |
NTIS Prices |
PC A06/MF A01 |
Primary Description |
600/02 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
323737523 |
Origin |
NTIS |
Type |
CAT |