Main Title |
Mutagenicity Evaluations of No. A 51 and No. D 202 Glycidyl Acrylate in the Ames Salmonella/Microsome Plate Test. (Final Reports) with Cover Letter dated 01/04/79. |
CORP Author |
Thiokol Corp., Trenton, NJ. ;Litton Bionetics, Inc., Kensington, MD.;Environmental Protection Agency, Washington, DC. Office of Toxic Substances. |
Publisher |
12 Dec 1978 |
Year Published |
1978 |
Report Number |
8EHQ-0179-0270; |
Stock Number |
OTS-0200452 |
Additional Subjects |
Toxicity ;
Salmonella ;
Microsomes ;
Mutagenes ;
Chemical compounds ;
Physiology ;
Liver ;
Enzymes ;
Rats ;
In vitro analysis ;
Evaluation ;
Dosage ;
Strains ;
Metabolism ;
Glycidyl acrylate ;
Thiokol Corporation
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
OTS-0200452 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
30p |
Abstract |
The test compound was examined for mutagenic activity in a series of in vitro microbial assays employing Salmonella indicator organism. The compound was tested directly and in the presence of liver microsomal enzyme preparations from Aroclor-induced rats. The compound was tested over a series of concentrations such that there was either quantitative or qualitative evidence of some chemically-induced physiological effect at the highest dose level. The low dose in all cases was below a concentration that demonstrated any toxic effect. The dose range employed for the evaluation of this compound was from 0.005 ul to 10 ul per plate. The compound was toxic to all the strains at 10 ul per plate. Toxicity was also observed at 5 ul per plate with the strains TA-1535, TA-1537 and TA-1538. |
Supplementary Notes |
The quality of the documents listed in the Office of Toxic Substances database may not meet usual NTIS standards but are included to further the opportunity for the scientific and technical community to locate materials which may not be available elsewhere. The content is the responsibility of OTS. Prepared in cooperation with American Petroleum Inst., Washington, DC. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
57Y; 57F; 57S |
NTIS Prices |
PC A03/MF A01 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
035500910 |
Origin |
NTIS |
Type |
CAT |