Record Display for the EPA National Library Catalog

RECORD NUMBER: 852 OF 3684

OLS Field Name OLS Field Data
Main Title Environmental technology verification report : field portable gas chromatograph/mass spectrometer, Viking Instruments Corporation Spectra Trak 672 /
Author Enfield, W. ; Bender, S. F. ; Keenan, M. R. ; Thornberg, S. M. ; Hightower, M. M.
Other Authors
Author Title of a Work
Einfeld, Wayne.
CORP Author Sandia National Labs., Albuquerque, NM.
Publisher U.S. Environmental Protection Agency,
Year Published 1997
Report Number EPA 600-R-97-148
Stock Number ADA364012
OCLC Number 40306791
Subjects Soils--Sampling. ; Soil pollution. ; Gas chromatography.
Additional Subjects Portable equipment ; Mass spectrometers ; Gas chromatography ; Integrated systems ; Verification ; Chemical contamination ; Liquids ; Soils ; Organic compounds ; Environmental management ; Chemical analysis ; Field equipment ; Serdp(Strategic environmental research and development program) ; Serdp collection ; Viking spectratrak 672 (T) ; Hewlett packard quadrupole mass spectrometer ; Voc(Volatile organic compound)
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30003LW0.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAD  EPA/600-R-97-148 Region 1 Library/Boston,MA 01/15/1999
EJAD  EPA 600/R-97-148 HWTIC Region 3 Library/Philadelphia, PA 10/22/1999
EJBD ARCHIVE EPA 600-R-97-148 Headquarters Library/Washington,DC 02/19/2016
EJBD  EPA 600-R-97-148 Headquarters Library/Washington,DC 02/14/2019
EJDD  EPA/600/R-97/148 OASQA Library/Fort Meade,MD 03/26/1999
EKAM  EPA 600-R-97-148 Region 4 Library/Atlanta,GA 02/12/1999
EKBD  EPA-600/R-97-148 Research Triangle Park Library/RTP, NC 12/15/2000
ESAD  EPA 600-R-97-148 Region 10 Library/Seattle,WA 12/04/1998
NTIS  ADA364012 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation xv, [84] pages : illustrations ; 28 cm
Abstract
The Viking SpectraTrak (Trademark) 672 GC/MS is an integrated system combining a temperature programmable gas chromatograph combined with a Hewlett Packard quadrupole mass spectromoter. This self-contained, field transportable system, whose design has been adapted from laboratory technology, uses a contained, chromatographic column and accompanying mass spectrometer to provide separation, identification, and quantification of volatile and semi-volatile organic compounds in sample matrices that include soil, liquid, and gas. The column enables the separation of individual analytes in complex mixtures. A mass spectrum, produced for each compound in the sample, can be used for compound identification and quantification. An integrated computer and data acquisition system enables identification and quantification of the analytes by comparison of detector response with a calibration table constructed from standards of known concentration. The system provides detection limits that range from about 5 ppm for direct gas injection to as low as 5 ppb for many volatile and semi-volatile organic contaminants in soils and liquids.
Notes
"EPA 600-R-97-148." "December 1997."