Main Title |
Prototype Evaluation of Commercial Second Generation Low-NO Burner Performance and Sulfur Capture. |
Author |
Lisauskas, R. A. ;
Itse, D. C. ;
|
CORP Author |
Riley Stoker Corp., Worcester, MA.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Year Published |
1986 |
Report Number |
EPA-68-02-3913; EPA/600/7-86/026; |
Stock Number |
PB86-220407 |
Additional Subjects |
Burners ;
Air pollution control ;
Nitrogen oxides ;
Combustion products ;
Coal ;
Sorbents ;
Calcium oxides ;
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB86-220407 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
286p |
Abstract |
The report gives results of pilot-scale combustion tests of a Riley Stoker second-generation low-NOx burner combined with dry sorbent injection for SO2 control. The burner design is based on the distributed mixing concept. Combustion tests were conducted at 100 million Btu/hr in EPA's Large Watertube Simulator (LWS) test furnace. Results were obtained for three U.S. coals and two sorbents. NOx was reduced up to 60% with the advanced burner design. |