Main Title |
At-sea incineration, evaluation of waste flow and combustion gas monitoring instrumentation onboard the M/T Vulcanus / |
Author |
Ackerman, D. A. ;
Johnson, R. J. ;
Moon, E. L. ;
Samsonov, A. E. ;
Scheyer, K. H.
|
Other Authors |
|
CORP Author |
TRW, Inc., Redondo Beach, CA.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor], |
Year Published |
1979 |
Report Number |
EPA-600/2-79-137; 68-02-2660; EPA-68-02-2660 |
Stock Number |
PB-299 198 |
OCLC Number |
08277301 |
Subjects |
Boats and boating--Waste disposal ;
Combustion gases--Analysis ;
Incineration
|
Additional Subjects |
Gas detectors ;
Incinerators ;
Chemical compounds ;
Water pollution control ;
Monitoring ;
Carbon monoxide ;
Carbon dioxide ;
Oxygen ;
Chlorine organic compounds ;
Motor tanker ;
Tanker ships ;
Gas analysis ;
Performance evaluation ;
Flowmeters ;
Air pollution ;
Cost analysis ;
Concentration(Composition) ;
Chemical analysis ;
Air pollution detection ;
Liquid wastes ;
Air pollution sampling ;
Vulcanus vessel
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EHAM |
EPA-600/2-79-137 |
|
Region 1 Library/Boston,MA |
05/25/2016 |
EJBD |
EPA 600-2-79-137 |
c.1 |
Headquarters Library/Washington,DC |
04/03/2014 |
ELBD ARCHIVE |
EPA 600-2-79-137 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ERAD |
EPA 600/2-79-137 |
|
Region 9 Library/San Francisco,CA |
10/01/2012 |
ESAD |
EPA 600-2-79-137 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-299 198 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
v, 100 pages : illustrations, forms ; 28 cm. |
Abstract |
The report describes the test operations and results of measuring organochlorine waste flowrate and CO, CO2, and O2 in the effluent gas during incineration of industrial chemical waste onboard the M/T Vulcanus. The data was obtained during shipboard test burns in the North Sea during November and December 1978 and February 1979. Program objectives were to gather data on durability and accuracy of both the waste flowmeters and the CO, CO2, and O2 monitoring system when used on a continuous routine basis. Combustion efficiency exceeded 99.95 percent in all cases, meeting IMCO requirements of 99.95 + or - 0.05 percent. The ultrasonic and vortex waste flowmeters and the CO, CO2, and O2 monitoring system performed satisfactorily during the burns. The CO, CO2, and O2 equipment was operated continuously for a maximum of 12 hours. The vortex flowmeters indicated gradual waste buildup, although buildup did not occur in the ultrasonic flowmeter piping. Monthly inspection and cleaning of the vortex meters would avoid extensive solids buildup. Use of spare instruments ensured continuous acquisition of combustion data throughout the burns. Post-test inspection of the analyzers indicated only minor corrosion and wear. |
Notes |
"TRW, Inc." "July 1979." Includes bibliographical references. "Contract no. 68-02-2660." |