Main Title |
Wall-Fired Boiler Design Criteria for Dry Sorbent SO2 Control with Low NOx Burners. |
Author |
Mongeon, R. K. ;
|
CORP Author |
Riley Stoker Corp., Worcester, MA.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Year Published |
1987 |
Report Number |
EPA-68-02-3912; EPA/600/7-87/021; |
Stock Number |
PB88-113485 |
Additional Subjects |
Boilers ;
Burners ;
Air pollution ;
Sulfur dioxide ;
Nitrogen oxides ;
Sorbents ;
Flue gases ;
Limestone ;
Coal ;
Design criteria ;
Stationary sources ;
Limestone Injection Multistage Burners
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB88-113485 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
414p |
Abstract |
The report assesses the impact of Limestone Injection Multistage Burner (LIMB) technology on wall-fired utility boilers for both new and retrofit designs. Recent attention has focused on dry sorbent sulfur dioxide (SO2) control technology which, in conjunction with low-nitrogen-oxide (low-NOx) burners, can reduce the two main acid rain precursors, SO2 and NOx. Riley Stoker wall-fired boilers are used for the survey and compared with the entire wall-fired, coal-fired utility boiler population. The influence of dry sorbents and staged combustion burners on boiler design was reviewed, and potential problem areas are noted. The review covers the sorbent (including storage and handling), the boiler and its appurtenances, and related flue gas cleanup and handling system. |
Supplementary Notes |
Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
NTIS Title Notes |
Final rept. Feb 83-Feb 85. |
PUB Date Free Form |
Sep 87 |
Category Codes |
41; 94; 68A |
NTIS Prices |
PC A18/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
736520545 |
Origin |
NTIS |
Type |
CAT |