Main Title |
Reduction of Membrane Fouling by Physical, Chemical and Biological Pretreatment. |
Author |
Solomon, T. L. ;
Summers, R. S. ;
Speth, T. F. ;
|
CORP Author |
Cincinnati Univ., OH. Dept. of Civil and Environmental Engineering. ;CTI Environmental, Louisville, KY. ;Cincinnati Univ., OH. Dept. of Civil and Environmental Engineering. |
Publisher |
1994 |
Year Published |
1994 |
Report Number |
EPA/600/A-94/014; |
Stock Number |
PB94-141546 |
Additional Subjects |
Water treatment ;
Membranes ;
Filtration ;
Water purification ;
Potable water ;
Filters ;
Flux(Rate) ;
Fouling ;
Coagulation ;
Gelation ;
Adsorption ;
Ozonization ;
Sanitary engineering ;
Reprints ;
Water pretreatment ;
Microfiltration ;
Biofiltration
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB94-141546 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
17p |
Abstract |
The use of different pretreatment processes to evaluate the reduction in membrane fouling due to pretreatment is discussed. Microfiltration, GAC filtration, alum coagulation, biofiltration, and ozonation/biofiltration are investigated. A hydrophobic UF membrane is used. The results suggest that processes that can reduce fouling, in order of best to worst, are: ozonation/biofiltration, biofiltration, coagulation, GAC adsorption, and microfiltration. |
Supplementary Notes |
Pub. in American Water Works Association Jnl., p159-186 1993. Prepared in cooperation with CTI Environmental, Louisville, KY., and Cincinnati Univ., OH. Dept. of Civil and Environmental Engineering. |
Title Annotations |
Reprint: Reduction of Membrane Fouling by Physical, Chemical and Biological Pretreatment. |
Category Codes |
50B; 68D; 48B; 99B |
NTIS Prices |
PC A03/MF A01 |
Primary Description |
600/14 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
409119751 |
Origin |
NTIS |
Type |