Main Title |
Air and pollutant movement in buildings can be evaluated using CO as a surrogate / |
Author |
Jackson, Merrill D. ;
Sparks, L. E. ;
Tichenor, B. A. ;
Guo, Z. ;
Krebs, K. A.
|
Other Authors |
|
CORP Author |
Acurex Corp., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Air and Energy Engineering Research Laboratory, |
Year Published |
1990 |
Report Number |
EPA/600/D-90/092; AEERL-P-663; EPA-68-02-4701 |
Stock Number |
PB90-262957 |
Additional Subjects |
Indoor Air '90, July 29-August 3 : (--1990 :--Toronto, Canada) ;
Aerosols ;
Residential buildings ;
Air flow ;
Carbon monoxide ;
Concentration(Composition) ;
Chemical analysis ;
Mass spectroscopy ;
Experimental design ;
Environmental engineering ;
Indoor air pollution ;
Tracer studies ;
Air pollution sampling ;
Air pollution detection ;
Ethylene/perchloro ;
Air quality
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB90-262957 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
9 pages ; 28 cm |
Abstract |
The paper discusses tracer tests conducted to determine how indoor conditions may affect pollutant levels, prior to initiating a study of the indoor use of aerosol products. (NOTE: Aerosol product use indoors can cause elevated concentrations of vapor-phase organic compounds.) Carbon monoxide (CO) was chosen to represent gas-phase emissions from aerosol products. CO is easy to monitor over a range of 0-200 ppm, and background levels expected in indoor environments are quite low (<1-3 ppm). CO was released in the bathroom of a test house, and CO distribution throughout the house was followed under several scenarios, including: a bathroom vent fan on/off, the furnace fan on/off, doors open/closed, and windows open/closed. Because of the concentration of CO used, a safety plan was in effect during all tests. The ability to use CO as a surrogate was evaluated by using a commercially available home spot remover containing perchloroethylene (perc). The product was used per package directions and released in the same location and conditions used in the CO tests. The distribution of perc was followed using gas chromatography. The results of the air movement study and the evaluation of how well CO can serve as a surrogate are presented. |
Notes |
Caption title. "EPA/600/D-90/092." "Merril D. Jackson, project officer." Microfiche. |
Place Published |
Research Triangle Park, NC : |
Supplementary Notes |
Presented at Indoor Air 1990, Toronto, Canada, July 29-August 3, 1990. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Research and Development. ; Air and Energy Engineering Research Laboratory. ; Acurex Corporation. |
PUB Date Free Form |
1990. |
NTIS Prices |
PC A02/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20001213183225 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01530nam 2200361Ka 45020 |