Main Title |
Radon diagnostics for schools / |
Author |
Leovic, Kelly W. ;
Craig, A. B. ;
Harris, D. B.
|
Other Authors |
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Air and Energy Engineering Research Laboratory, |
Year Published |
1990 |
Report Number |
EPA/600/D-90/105; AEERL-P-667 |
Stock Number |
PB90-262825 |
Additional Subjects |
Annual AWMA Conference, June 24-29 :--1990 :--Pittsburgh, PA ;
Radon ;
School buildings ;
Measurement ;
Environmental engineering ;
Subgrades ;
Engineering drawings ;
Specifications ;
Ventilation ;
Field tests ;
Environmental surveys ;
Indoor air pollution ;
Diagnostic techniques ;
HVAC systems ;
Stationary pollutant sources
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB90-262825 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
12 pages ; 28 cm |
Abstract |
The paper discusses a systematic approach to conducting radon diagnostics in schools. It provides those with radon mitigation experience in houses with an understanding of the major differences between schools and houses and how these differences influence radon diagnostics in schools. The diagnostic procedures and measurements discussed include: a review of all radon screening and confirmatory measurements; a review of all available building specifications and drawings such as structural, mechanical, and electrical; a building investigation to assess potential radon entry routes and to confirm and supplement information cited in the building plans; an analysis of the heating, ventilating, and air-conditioning (HVAC) system and its influence on pressure differentials and radon levels; and, most importantly for schools considering installation of a subslab depressurization system, the recommended approaches for measuring subslab pressure field extension. Radon diagnostic protocols for schools need to be more extensive than those applied in houses since schools are typically much larger than houses and often have complex structural details and HVAC systems. |
Notes |
Caption title. "EPA/600/D-90/105." "Kelly W. Leovic, project officer." Microfiche. |
Contents Notes |
EPA/600/D-90/105. |
Place Published |
Research Triangle Park, NC : |
Supplementary Notes |
Presented at the Annual AWMA Conference, Pittsburgh, PA., June 24-29, 1990. |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Research and Development. ; Air and Energy Engineering Research Laboratory. |
PUB Date Free Form |
1990. |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20001213144641 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01247cam 2200301Ka 45170 |