Main Title |
Development of a Rationally Based Design Protocol for the Ultraviolet Light Disinfection Process. |
Author |
Scheible, O. K. ;
|
CORP Author |
HydroQual, Inc., Mahwah, NJ.;Environmental Protection Agency, Cincinnati, OH. Water Engineering Research Lab. |
Year Published |
1987 |
Report Number |
EPA/600/J-87/005; |
Stock Number |
PB87-176970 |
Additional Subjects |
Disinfection ;
Ultraviolet radiation ;
Design criteria ;
Mathematical models ;
Waste water ;
Water treatment ;
Bacteria ;
Ultraviolet lamps ;
Reprints ;
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB87-176970 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
10p |
Abstract |
A protocol is demonstrated for the design and evaluation of ultraviolet (UV) disinfection systems based on a mathematical model. The disinfection model incorporates the system's physical dimensions, the residence time distribution of the reactor and dispersion characteristics, the UV intensity within the reactor, and the quality of the wastewater being treated. The data requirements for calibration of the model are discussed. An example is then given, using information from a pilot study at the Port Richmond Water Pollution Control Plant, New York, New York. Reactor hydraulics are characterized in terms of the dispersion coefficient and the dispersion number. Intensity is computed by the point source summation method; this is adjusted by attenuation factors to account for surface fouling of the UV lamp enclosures and the aging of the lamps. Water quality is related to the UV absorbance coefficient, the initial bacterial density, and the suspended solids (SS). The bacteria inactivation rate is related to the intensity of the reactor, while bacteria occluded by particulate matter, and unaffected by UV, are described as a function of the SS concentration. (Copyright (c) J. Water Pollution Control Federation, 59(1):25-31, January 1987.) |
Supplementary Notes |
Pub. in Jnl. of Water Pollution Control Federation, v59 n1 p25-31 Jan 87. Sponsored by Environmental Protection Agency, Cincinnati, OH. Water Engineering Research Lab. |
NTIS Title Notes |
Journal article. |
Title Annotations |
Reprint: Development of a Rationally Based Design Protocol for the Ultraviolet Light Disinfection Process. |
PUB Date Free Form |
c1987 |
Category Codes |
68D; 50B |
NTIS Prices |
PC A02/MF A01 |
Primary Description |
600/14 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
716921418 |
Origin |
NTIS |
Type |
CAT |