Main Title |
Experimental investigation of PIC formation in CFC incineration / |
Author |
Hall, Robert E. ;
Lee, C. W. ;
Hassel, G. R. ;
Ryan, J. V.
|
Other Authors |
|
CORP Author |
Energy and Environmental Research Corp., Irvine, CA. ;Acurex Corp., Research Triangle Park, NC. Environmental Systems Div.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Air and Energy Engineering Research Laboratory, |
Year Published |
1991 |
Report Number |
EPA/600/A-92/021; EPA-68-C0-0094 |
Stock Number |
PB92-150432 |
Subjects |
Chlorofluorocarbons--Combustion ;
Air--Pollution ;
Products of incomplete combustion
|
Additional Subjects |
Combustion efficiency ;
Incinerators ;
Freons ;
Air pollution sampling ;
Waste disposal ;
Fluorohydrocarbons ;
Chlorohydrocarbons ;
Combustion products ;
Aromatic polycyclic hydrocarbons ;
Concentration(Composition) ;
Destruction ;
Experimental design ;
Polychlorinated dibenzodioxins ;
Polychlorinated dibenzofurans ;
Dichlorodifluoromethane ;
Freon 11 ;
Freon 12
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB92-150432 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
8 pages : illustrations |
Abstract |
The paper gives results of bench-scale tests to characterize combustion emissions from chlorofluorocarbon (CFC-11 and -12) incineration. The destruction efficiencies (DEs) of the CFCs and the major products of incomplete combustion (PICs) from each CFC were determined. DEs of at least 99.999% can be attained repeatedly for both CFCs. Major PICs identified were non-halogenated: toluene and xylene were found most frequently. PIC concentrations were independent of the CFC concentration in the fuel. Sampling was performed one time to screen for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) and polyaromatic hydrocarbons (PAHs) while incinerating CFC-12. Even with a DE of greater than 99.999%, high levels of PCDD/PCDF were formed. The extensive PCDD/PCDF formation apparently occurred in the absence of entrained particulate matter. |
Notes |
Paper presented at ENVIRONMZXASIA/WATZRMZXASIA92 Conference, Singapore, Feb. 1992. Key words: pollution; incinerators; halohydrocarbons; combustion; emmission; sampling; furans; pollution control; stationary sources; chlorofluorocarbons; destruction efficiency; products of incomplete combustion; dioxins. Includes bibliographical references (p. 4-5). Microfiche. |
Place Published |
Research Triangle Park, N.C. : |
Supplementary Notes |
See also PB90-116955 and PB92-126952. Presented at ENVIRONMZXASIA/WATZRMZXASIA92 Conference, Singapore, February 18-21, 1992. Prepared in cooperation with Acurex Corp., Research Triangle Park, NC. Environmental Systems Div. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Corporate Au Added Ent |
Air and Energy Engineering Research Laboratory. ; Energy and Environmental Research Corp. |
PUB Date Free Form |
1991. |
NTIS Prices |
PC A02/MF A01 |
BIB Level |
m |
Medium |
microform |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20010202130518 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01856cam 2200385Ia 45020 |