Main Title |
Method 1622: 'Cryptosporidium' in Water by Filtration/IMS/FA. (December 2005). |
CORP Author |
Environmental Protection Agency, Washington, DC. Office of Water. |
Publisher |
Dec 2005 |
Year Published |
2005 |
Report Number |
EPA/815/R-05/001; |
Stock Number |
PB2006-111227 |
Additional Subjects |
Cryptosporidium ;
Immunomagnetic separation ;
Filtration ;
Microorganisms ;
Pathogens ;
Parasitic diseases ;
Waterborne diseases ;
Drinking water ;
Quality control ;
Contamination ;
Safety ;
Sampling ;
Pollution prevention ;
Waste management ;
EPA Methods 1622 ;
Immunofluorescence
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2006-111227 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
80p |
Abstract |
To support future regulation of protozoa in drinking water, the Safe Drinking Water Act Amendments of 1996 require the U.S. Environmental Protection Agency (EPA) to evaluate the risk to public health posed by drinking water contaminants, including waterborne parasites, such as Cryptosporidium. To implement these requirements, EPA must assess Cryptosporidium occurrence in raw surface waters used as source waters for drinking water treatment plants. EPA Method 1622 was developed to support this assessment. EPA initiated an effort in 1996 to identify new and innovative technologies for protozoan monitoring and analysis. After evaluating potential alternatives to the then-current method through literature searches, discussions with research and commercial laboratories, and meetings with experts in the field, the Engineering and Analysis Division within the Office of Science and Technology within EPA's Office of Water developed draft Method 1622 for Cryptosporidium detection in December 1996. This Cryptosporidum-only method was validated through an interlaboratory study in August 1998, and was revised as a final, valid method for detecting Cryptosprodium in water in January 1999. |
Supplementary Notes |
See also rept. dated Apr 01, PB2002-108709. |
Availability Notes |
Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
68D; 57J; 99A |
NTIS Prices |
PC A06/MF A01 |
Primary Description |
100/00 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
019201240 |
Origin |
NTIS |
Type |
CAT |