Main Title |
Environmental Technology Verification Report. Ground Water Sampling Technologies, Geoprobe Inc., Mechanical Bladder Pump, MP470. |
Author |
Einfeld, W. ;
Koglin, E. N. ;
|
CORP Author |
Sandia National Labs., Albuquerque, NM.;Environmental Protection Agency, Las Vegas, NV. National Exposure Research Lab. |
Publisher |
Aug 2003 |
Year Published |
2003 |
Report Number |
EPA/600/R-03/086; |
Stock Number |
PB2004-100983 |
Additional Subjects |
Ground water ;
Water sampling ;
Technology assessment ;
Performance testing ;
Environmental monitoring ;
Inorganic cations ;
Site characterization ;
Samplers ;
Quality assurance ;
Pumps ;
Remediation ;
Monitoring wells ;
Environmental protection ;
Mechanical bladder pump ;
Volatile organic chemicals ;
Bladder pumps
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2004-100983 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
60p |
Abstract |
The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification Program (ETV) to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the ETV Program is to further environmental protection by accelerating the acceptance and use of improved and cost-effective technologies. ETV seeks to achieve this goal by providing high-quality, peer-reviewed data on technology performance to those involved in the design, distribution, financing, permitting, purchase, and use of environmental technologies. Verification of contaminated site characterization and monitoring technologies is carried out within the Advanced Monitoring Systems (AMS) Center, one of seven ETV verification centers. Sandia National Laboratories, a Department of Energy laboratory, is one of the verification testing organizations within this ETV Center. Sandia collaborated with personnel from the US Geological Survey and Tyndall Air Force Base to conduct a verification study of ground-water sampling technologies for deployment in narrow-bore, direct-push wells at contaminated sites with potential ground-water contamination. This verification statement provides a summary of the results from a verification test of the Model MP470 Mechanical Bladder Pump manufactured by Geoprobe Systems Inc. |
Supplementary Notes |
Sponsored by Environmental Protection Agency, Washington, DC. Office of Research and Development. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
68D; 48G |
NTIS Prices |
PC A05/MF A01 |
Primary Description |
100/00 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
001400170 |
Origin |
NTIS |
Type |
CAT |