Main Title |
Flow Reference Method Testing and Analysis; Field Test Plan. Texas Utilities Decordova Steam Electric Station. |
Author |
Lieberman, E. ;
Werner, A. S. ;
|
CORP Author |
Cadmus Group, Inc., Durham, NC.;Environmental Protection Agency, Washington, DC. Acid Rain Div. |
Publisher |
30 May 1997 |
Year Published |
1997 |
Report Number |
EPA-68-D2-0168; EPA/430/R-97/024; |
Stock Number |
PB99-150336 |
Additional Subjects |
Steam generators ;
Air pollution monitors ;
Flue gases ;
Volume ;
Flow rates ;
Velocity ;
Experimental design ;
Planning ;
Field tests ;
Air pollution sampling ;
Stack gases ;
Emissions ;
Electric power plants ;
Flow measurement ;
Gas flow ;
Test methods ;
Yaw ;
Pitch(Motion) ;
Angles ;
Probes ;
Electric utilities ;
Acid rain ;
Air pollution effects ;
Texas ;
EPA Method 2 ;
Decordova Steam Electric Station ;
CEMS(Continuous Emission Monitoring Systems) ;
Acid Rain Program
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB99-150336 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
266p |
Abstract |
This report describes the experiemental design and test plan for the first of three field tests that the U.S. Environmental Protection Agency (EPA) conducted in 1997 as part of a major study to evaluate potential improvements to Method 2, EPA's test method for measuring flue gas volumetric flow in stacks. The experimental design involved four test teams taking concurrent in-stack measurements with velocity sensing probes. Seven types of probes were included in the study. Three test matrices were used to gather data for inter-probe and inter-team comparisons and to assess the impact of velocity decline near the stack wall on volumetric flow measurements. |
Supplementary Notes |
See also PB99-150310, PB99-150328, PB99-150286, PB99-150294, PB99-150401, PB99-150385 and PB99-150369. For complete data base on zip disk see PB99-150393. Sponsored by Environmental Protection Agency, Washington, DC. Acid Rain Div. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
68A; 99F; 97I; 97R |
NTIS Prices |
PC A13/MF A03 |
Primary Description |
100/00 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
930200560 |
Origin |
NTIS |
Type |
CAT |