Main Title |
Environmental Assessment of a Watertube Boiler Firing a Coal-Water Slurry. Volume 2. Data Supplement. |
Author |
DeRosier, R. ;
Waterland, L. R. ;
|
CORP Author |
Acurex Corp., Mountain View, CA. Energy and Environmental Div.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Year Published |
1986 |
Report Number |
EPA-68-02-3188; EPA/600/7-86/004B; |
Stock Number |
PB86-183308 |
Additional Subjects |
Water tube boilers ;
Air pollution control ;
Slurries ;
Sampling ;
Boilers ;
Industrial wastes ;
Coal water slurries ;
Stationary sources
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB86-183308 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
195p |
Abstract |
The report is a compendium of detailed test sampling and analysis data obtained in field tests of a watertube industrial boiler burning a coal/water slurry (CWS). Test data included in the report include preliminary stack test data, boiler operating data, and complete flue gas emission results. Flue gas emission measurements included continuous monitoring for criteria pollutants; onsite gas chromatography (GC) for volatile hydrocarbons (Cl-C6); Methods 5/8 sampling for particulate, SO2, and SO3 emissions; source assessment sampling system (SASS) for total organics in two boiling point ranges (100 to 300 C and > 300 C), organic compound category information using infrared spectrometry (IR), liquid column (LC) chromatography separation, and low resolution mass spectrometry (LRMS), specific quantitation of the semivolatile organic priority pollutants using gas chromatography/mass spectrometry (GC/MS), and trace element emissions using spark source mass spectrometry (SSMS) and atomic absorption spectroscopy (AAS); N2O emissions by gas chromatography electron capture detector (GC/ECD); and biological assay testing of SASS and ash stream samples. |
Supplementary Notes |
See also PB86-159845. Portions of this document are not fully legible. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
NTIS Title Notes |
Final rept. Jan 84-Mar 85. |
PUB Date Free Form |
Feb 86 |
Category Codes |
7D; 68A; 99A |
NTIS Prices |
PC A09/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
614227176 |
Origin |
NTIS |
Type |
CAT |