Main Title |
Dual process high-rate filtration of raw sanitary sewage and combined sewer overflows / |
Author |
Innerfeld, Hank, ;
Forndran, Angelika ;
Ruggiero, Dominick D. ;
Hartman, Thomas J.
|
Other Authors |
|
CORP Author |
Municipal Environmental Research Laboratory. |
Publisher |
Environmental Protection Agency, Office of Research and Development, Municipal Environmental Research Laboratory ; for sale by the National Technical Information Service, |
Year Published |
1979 |
Report Number |
EPA-600/2-79-015; EPA-S-803271 |
Stock Number |
22161 |
OCLC Number |
05112189 |
ISBN |
pbk. |
Subjects |
Combined sewer overflows ;
Sewage--Purification--Filtration ;
Combined sewers--Overflows
|
Additional Subjects |
Sewage treatment ;
Combined sewers ;
Sewage filtration ;
Overflows ;
Pilot plants ;
Performance evaluation ;
Size screening ;
Biochemical oxygen demand ;
Cost analysis ;
Capitalized costs ;
Operating costs ;
Comparison ;
Design ;
Process charting ;
Field tests ;
Chemical oxygen demand
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EHAM |
TD662.D82 |
|
Region 1 Library/Boston,MA |
04/29/2016 |
EJBD |
EPA 600/2-79-015 |
c.1 |
Headquarters Library/Washington,DC |
01/14/2014 |
ELBD ARCHIVE |
EPA 600/2-79-015 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 600-2-79-015 |
|
AWBERC Library/Cincinnati,OH |
08/06/1993 |
ESAD |
EPA 600-2-79-015 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-296 626 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xii, 105 pages : illustrations, map ; 28 cm. |
Abstract |
Pilot plant studies were conducted at New York's Newtown Creek Water Pollution Control Plant from 1975-1977 to investigate the suspended solids (SS) removal capabilities of the deep bed, high rate gravity filtration process on raw sewage and combined sewer overflows. The treatment system was composed of a rotating screen followed by a dual media, and high rate filter. A continuous series of tests on dry weather (raw sewage) flows demonstrated SS removals across the filter averaging 67 percent. Tests on combined sewer overflow and average removal of 61 percent SS across the filter. Capital costs (ENR-2520) for a high rate filtration plant are estimated at $55,225 per mgd for a 200 mgd plant (757,000 cu m/day). Total annual treatment costs, including amortization, operation and maintenance charges, range from approximately $396,450 to $1,794,050 for dual treatment facilities in a 25 to 200 mgd (94,600 to 757,000 cu m/day) capacity range and $238,050 to $1,175,900 for the same capacity range of facilities treating only CSO. Comparison with alternative treatment systems show that HRF is cost competitive with conventional sedimentation facilities for dual-process or CSO treatment yet HRF has on 5-7 percent the area requirements. For strict CSO treatment, HRF is competitive with dissolved air flotation and microstraining processes. |
Notes |
Grant no. S-803271. March 1979. Includes bibliographical references. |
Place Published |
Cincinnati, Ohio Springfield, Va. |
Supplementary Notes |
See also report dated Apr 72, PB-211 144. Prepared in cooperation with Nebolsine, Kohlmann, Ruggiero, New York. |
Corporate Au Added Ent |
Municipal Environmental Research Laboratory,; New York (N.Y.). Bureau of Water Resources, |
Corp Au Ser Add Ent |
United States. Environmental Protection Agency. Environmental protection technology series ; EPA-600/2-79-015. |
PUB Date Free Form |
1979 |
Series Title Untraced |
Environmental protection technology series ; EPA-600/2-79-015 |
NTIS Prices |
PC A06/MF A01 |
BIB Level |
m |
Medium |
unmediated |
Content |
text |
Carrier |
volume |
Cataloging Source |
OCLC/T |
Merged OCLC records |
1225652783 |
OCLC Time Stamp |
20160419143154 |
Language |
eng |
SUDOCS Number |
EP 1.23/2:600/2-79-015 |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01819cam 2200421Ii 45020 |