Main Title |
Construction quality assurance for hazardous waste land disposal facilities : public comment draft. |
Author |
Northeim, C. M. ;
Truesdale, R. S.
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC.;Environmental Protection Agency, Cincinnati, OH. Hazardous Waste Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Hazardous Waste Engineering Research Laboratory, |
Year Published |
1985 |
Report Number |
EPA 530-SW-85-021; OSWER Dir 9487.00-6c; EPA-68-02-3992 |
Stock Number |
PB86-136157 |
OCLC Number |
13074934 |
Subjects |
Hazardous waste sites--United States
|
Additional Subjects |
Hazardous waste facilities--United States ;
Hazardous materials ;
Licenses ;
Quality assurance ;
Construction management ;
Solid waste disposal ;
Linings ;
Leaching ;
Covers ;
Sampling ;
Sites ;
Membranes ;
Permeability ;
Public opinion ;
Land disposal ;
Waste management
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
OSWER Dir 9487.00-6C |
|
Headquarters Library/Washington,DC |
03/20/2014 |
EKBD |
EPA-530/SW-85-021 |
|
Research Triangle Park Library/RTP, NC |
05/02/2003 |
ELBD ARCHIVE |
OSWER Dir 9487.00-6C |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
DISPERSAL |
ERAD |
EPA 530/SW-85-021 |
|
Region 9 Library/San Francisco,CA |
08/09/2012 |
ESAD |
EPA 530-SW-85-021 |
|
Region 10 Library/Seattle,WA |
04/15/2005 |
NTIS |
PB86-136157 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xii, 100 pages : illustrations ; 28 cm |
Abstract |
The document presents elements of a construction quality assurance plan that should be addressed during the permit application procedure for a specific site. These elements include: (1) areas of responsibility and lines of authority in executing the plan; (2) requisite qualifications of the construction quality assurance personnel; (3) observations and tests to be performed as part of quality assurance activity during construction; (4) sampling requirements (including sampling frequency, size, and location; acceptance and rejection criteria; and corrective action procedures); and (5) documentation. The document also discusses management of quality for the construction or installation of foundations, dikes, low-permeability soil liners, flexible membrane liners, leachate collection systems, and cover systems. |
Notes |
"October 1985." "EPA/530-SW-85-021." "OSWER Dir 9487.00-6c." |