Record Display for the EPA National Library Catalog
RECORD NUMBER: 313 OF 1103Main Title | Full-Scale Desulfurization of Stack Gas by Dry Limestone Injection. Volume III. Appendices I through L. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Author | Gartrel, F. E. ; | |||||||||||
CORP Author | Tennessee Valley Authority, Chattanooga. Div. of Environmental Planning. | |||||||||||
Year Published | 1973 | |||||||||||
Report Number | TV-30541A; 650/2-73-019-c; | |||||||||||
Stock Number | PB-230 385 | |||||||||||
Additional Subjects | Air pollution ; Sulfur oxides ; Electric power plants ; Limestone ; Fly ash ; Utilization ; Chemical reactivity ; Mineral deposits ; Mathematical models ; Cost estimates ; Capitalized costs ; Operating costs ; Air pollution control ; Limestone injection ; Dry methods | |||||||||||
Holdings |
|
|||||||||||
Collation | 343p | |||||||||||
Abstract | The report gives results of a test program of dry limestone injection, demonstrated on a 150-Mw pulverized-coal-fired boiler at TVA's Shawnee Plant. The program included: equipment shakedown, dust distribution studies, process optimization, and long-term injection trials. The program is discussed in context with previous investigations and EPA-sponsored support activities. Appendices contain test program detail results and results of EPA support projects. Because of low SO2 removal efficiencies and the potential for major reliability problems, it does not appear that dry limestone injection will play an important role in controlling SO2 emissions from power plants. |