Main Title |
Presence-Absence Coliform Test for Monitoring Drinking Water Quality. |
Author |
Rice, E. W. ;
Geldreich, E. E. ;
Read, E. J. ;
|
CORP Author |
Environmental Protection Agency, Cincinnati, OH. Risk Reduction Engineering Lab. ;Computer Sciences Corp., Cincinnati, OH. |
Publisher |
c1989 |
Year Published |
1989 |
Report Number |
EPA/600/J-89/527; |
Stock Number |
PB91-196196 |
Additional Subjects |
Water treatment ;
Potable water ;
Water pollution sampling ;
Coliform bacteria ;
Comparison ;
Materials recovery ;
Performance evaluation ;
Compliance ;
Pollution regulations ;
Reprints ;
Presence-absence test ;
Multiple fermentation tube procedure ;
Membrane filter technique
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB91-196196 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
8p |
Abstract |
Data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure and the membrane filter technique. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P<0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P<0.01. The presence-absence test offers a viable alternative to water utilities using frequency-of-occurrence monitoring for compliance regulation. |