Main Title |
Construction quality control and post-construction performance verification for the Gilson Road hazardous waste site cutoff wall / |
Author |
Barvenik, Matthew J. ;
Ayres, J. E.
|
Other Authors |
|
CORP Author |
New Hampshire. Water Supply and Pollution Control Commission.; Hazardous Waste Engineering Research Laboratory (Cincinnati, Ohio) |
Publisher |
Hazardous Waste Engineering Research Laboratory, U.S. Environmental Protection Agency, |
Year Published |
1987 |
Report Number |
EPA/600/2-87/065 |
Stock Number |
PB88-113295 |
OCLC Number |
17159422 |
Subjects |
Hazardous waste sites--New Hampshire--Nashua
|
Additional Subjects |
Hazardous wastes ;
Hazardous materials ;
Containment ;
Walls ;
Water pollution control ;
Construction ;
Design criteria ;
Soils ;
Bentonite ;
Backfills ;
Field tests ;
Hydraulic conductivity ;
Stress ;
Evaluation ;
Trenching ;
Excavation ;
Slurries ;
Methylene blue ;
Ground water ;
Monitoring ;
Permeameters ;
Cutoff walls ;
Superfund
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EHAM |
EPA/600/2-87/065 |
|
Region 1 Library/Boston,MA |
05/25/2016 |
EIAD |
EPA/600/2-87/065 |
|
Region 2 Library/New York,NY |
07/18/2003 |
EJBD |
EPA-600/2-87-065 |
|
Headquarters Library/Washington,DC |
07/09/2013 |
EKBD |
EPA-600/2-87-065 |
|
Research Triangle Park Library/RTP, NC |
01/01/1988 |
ELBD ARCHIVE |
EPA 600-2-87-065 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
DISPERSAL |
EMBD |
PB88-113295 MF |
|
NRMRL/GWERD Library/Ada,OK |
06/26/1992 |
ESAD |
EPA 600-2-87-065 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB88-113295 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
1 volume (various pagings) : illustrations, maps ; 28 cm |
Abstract |
The report describes assessment activities undertaken to evaluate the effectiveness of a soil/bentonite backfilled cutoff wall (slurry trench) installed for the purpose of hazardous waste containment. The work includes development and evaluation of field quality control tests, evaluation of electronic piezocone instrumentation for post-construction verification of backfill homogeneity, and evaluation of cutoff wall bulk hydraulic conductivity via hydraulic stress testing. The information in the report is useful to those involved in the feasibility study, design and/or construction of cutoff walls as a hazardous waste remediation technology. |
Notes |
Distributed to depository libraries in microfiche. "August 1987." "Water Supply and Pollution Control Commission, State of New Hampshire." Includes bibliographical references (pages 6-1-6-3). "EPA/600/2-87/065." |