RECORD NUMBER: 3 OF 3Main Title | Upper Ash Pond Dam--A.B. Brown Station Assessment Report. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CORP Author | Lockheed Martin Corp., Bethesda, MD.; Environmental Protection Agency, Washington, DC. | |||||||||||
Year Published | 2009 | |||||||||||
Stock Number | PB2010-101503 | |||||||||||
Additional Subjects | Dam safety ; Impoundment assessments ; Coal-fired generating plant ; Structural stability ; Landfills ; Electric generating station ; Waste ash ; Site specific assessments ; Coal combustion ; Construction practices ; Hazard potential ; Coal combustion wastes (CCW) ; A B Brown Generating Station ; Evansville Illinois | |||||||||||
Holdings |
|
|||||||||||
Collation | 36p | |||||||||||
Abstract | The purpose of this work is to provide a Dam Safety Assessment of CCW management units, including the following: (1) Identify conditions that may adversely affect the structural stability and functionality of a management unit and its appurtenant structures; (2) Note the extent of deterioration, status of maintenance, and/or need for immediate repair; (3) Evaluate conformity with current design and construction practices; and (4) Determine the hazard potential classification for units not currently classified by the management unit owner or by state or federal agencies. |