Record Display for the EPA National Library Catalog

RECORD NUMBER: 43 OF 434

Main Title Bench-Scale Evaluation of Coagulants for Low Turbidity Water.
Author Brink, D. R. ; Choi, S. I. ; Al-Ani, M. ; Hendricks, D. W. ;
CORP Author American Water Works Association, Denver, CO. ;Iowa State Univ., Ames. ;Scientific Research Center, Baghdad (Iraq).;Environmental Protection Agency, Cincinnati, OH. Water Engineering Research Lab.;Colorado State Univ., Fort Collins.
Publisher c1988
Year Published 1988
Report Number EPA/600/J-88/046;
Stock Number PB89-103337
Additional Subjects Turbidity ; Water quality ; Coagulants ; Water purification ; Water treatment ; Tests ;
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB89-103337 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 9p
Abstract
Because the conventional jar test is ineffective for determining optimal coagulant dosages for low turbidity waters, utilities employing rapid-rate filtration of such waters may fail to maximize treatment efficiency for lack of a simple bench-scale procedure for determining coagulant dosage. Using terms useful to water treatment plant operators, the article describes a simple bench-scale test for determining coagulant dosages for raw water supplies with turbidity levels of 1 ntu or less. The report covers the protocol for the jar-filtration test and documentation on test validity. (Copyright (c) Journal AWWA 1988.)