Main Title |
Aerosol measurements in the submicron size range : studies with an aerosol centrifuge, a new diffusion battery, a low pressure impactor and an advanced condensation nuclei counter / |
Author |
Preining, Othmar. ;
Berner, Axel
|
Other Authors |
|
CORP Author |
Vienna Univ. (Austria). Inst. for Experimental Physics.;Environmental Sciences Research Lab., Research Triangle Park, NC. Emissions Measurement and Characterization Div. |
Publisher |
U.S. Environmental Protection Agency, Environmental Sciences Research Laboratory, |
Year Published |
1979 |
Report Number |
EPA 600/2-79/105; EPA-R-801983 |
Stock Number |
PB-298 073 |
OCLC Number |
40343471 |
Subjects |
Air--Pollution--Measurement ;
Particle size determination ;
Aerosols--Measurement
|
Additional Subjects |
Aerosols ;
Particle size ;
Centrifuges ;
Air pollution ;
Sodium chloride ;
Laboratory equipment ;
Condensation nuclei ;
Design ;
Performance evaluation ;
Separation ;
Diffusion batteries ;
Numerical solution
|
Internet Access |
|
Local Library Info |
Library |
Local Subject |
Local Note |
EJB |
|
Photocopy (c.1) |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EHAM |
TD884.5.P74 1979 |
|
Region 1 Library/Boston,MA |
04/29/2016 |
EJBD |
EPA 600-2-79-105 |
|
Headquarters Library/Washington,DC |
01/16/2014 |
EKBD |
EPA-600/2-79-105 |
|
Research Triangle Park Library/RTP, NC |
07/04/2003 |
ELBD ARCHIVE |
EPA 600-2-79-105 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-2-79-105 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-298 073 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xiv, 93 pages : illustrations ; 28 cm. |
Abstract |
The report summarizes the investigations of four aerosol classifiers which cover finite, but overlapping ranges of the aerosol particle size spectrum. The first part is concerned with a cylindrical aerosol centrifuge, which measures aerodynamic equivalent diameters precisely. This instrument has been used as a reference instrument in diffusion battery experiments reported in the second part. The diffusion battery has been investigated for fairly large particle sizes (0.3 micrometer to 0.5 micrometer) to determine the influence of sedimentation, interception and impaction on the transmission of the diffusion battery. These experiments have been performed with highly monodispersed NaCl aerosols. In the third part a five stage low pressure impactor is described, which covers the size range from 0.1 micrometer to 25 micrometers diameter. It has been developed specifically for the determination of the deposited particulate mass. First data on mass-size distributions of atmospheric aerosols are reported. The final chapter summarizes the development of a special condensation nuclei counter which measures number-size distributions in the size range from 0.002 micrometers to 0.1 micrometers KELVIN-equivalent diameter. The applicability to urban atmospheric aerosols is demonstrated. |
Notes |
"EPA-600/2-79-105." EPA research grant no. 801983; EPA project officer: Jack Wagman. Includes bibliographical references (pages 87-91). |