Record Display for the EPA National Library Catalog

RECORD NUMBER: 42 OF 57

Main Title On-Site Digital Accumulation and Storage of Hydrologic Data for Use in Data Acquisition Systems.
Author Chadwic, Duane G. ;
CORP Author Utah Water Research Lab., Logan.
Year Published 1972
Report Number PRCWRRI-21-1; DI-14-31-0001-3245; OWRR-A-011-UTAH; 04067,; A-011-UTAH(1)
Stock Number PB-214 185
Additional Subjects ( Hydrometeorology ; Data acquisition) ; Analog to digital converters ; Remote sensing ; Data recording ; Water ; Rainfall ; Temperature ; Tape punches ; Power supplies ; Wind direction ; Wind velocity ;
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-214 185 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 30p
Abstract
Methods are discussed for measuring wind, water, and temperature, and recording the information in digital form at some given location remote from conventional 110 volt power source. Measurements of wind direction, wind miles, water level, rain fall, temperature, and the happening of miscellaneous events can all be recorded on standard 8-hole paper tape. The system is operable for several months, unattended. The data are recorded at precise predetermined intervals. Dry cell batteries supply the necessary power to operate the system. (Author)