Main Title Water Quality Basic Data. Report on Analytical Reference Sample Type I, BD-1.
CORP Author Robert A. Taft Sanitary Engineering Center, Cincinnati, Ohio.
Year Published 1958
Stock Number PB-227 769
Additional Subjects Water analysis ; Quantitative analysis ; Ammonia ; Chlorides ; Sulfates ; Alkalinity ; Hardness ; Turbidity ; pH ;
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-227 769 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 10p
Abstract
Sample type I, BD-1 is composed of water to be analyzed for ammonia, chloride, sulfate, dissolved solids, alkalinity, hardness, and turbidity. Participant laboratories analyzed samples of water analytically. Standard deviations were calculated and are presented. Results of each analysis are presented including the method used. Finally comments on the methods are presednted as are summary data tables. It is hoped that the following are provided: a statistical evaluation of procedures, the opportunity for laboratories to be compared, exchange of information, evidence suggesting methods requiring further development, and a framework for broad evaluations of new analytical methods.