Main Title |
Quality assurance of FBC H2SO4 measurements / |
Author |
Acciani, T. R. ;
Maddalone, R. F.
|
Other Authors |
|
CORP Author |
TRW Defense and Space Systems Group, Redondo Beach, CA.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
The Office ; Available to the public through the National Technical Information Service, |
Year Published |
1979 |
Report Number |
EPA-600/7-79-154; EPA-68-02-2613 |
Stock Number |
PB80-178452 |
OCLC Number |
07073562 |
Subjects |
Sulfuric acid ;
Air--Pollution--Measurement ;
Pollution control equipment ;
Air--Pollution--Measurement ;
Pollution control equipment ;
Sulfuric acid ;
Sulphuric acid
|
Additional Subjects |
Air pollution control ;
Fluidized bed processing ;
Sulfuric acid ;
Concentration(Composition) ;
Quality assurance ;
Industrial wastes ;
Combustion products ;
Volumetric analysis ;
Sampling ;
Air pollution detection ;
Stationary sources
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EKBD |
EPA-600/7-79-154 |
|
Research Triangle Park Library/RTP, NC |
12/19/2003 |
ELBD ARCHIVE |
EPA 600-7-79-154 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-79-154 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB80-178452 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
v, 26 p. : ill. ; 28 cm. |
Abstract |
The report gives results of a study to: evaluate existing data on H2SO4 measurements from fluidized-bed combustion (FBC) processes; determine the true value of the H2SO4 concentration which might have been obtained had the control condensation (Goksoyr/Ross) procedure been used; and run a material compatibility study to find alloys that can be used to fabricate a controlled condensation sampling system. The sampling system at Exxon's FBC facility was reviewed: H2SO4 values are about 12% low with another reduction of 10-25% because of low sampling temperatures and Balstron filters. The control condensation system with an acid/base titration using bromophenol blue as the indicator is the recommended sampling/analysis method for H2SO4 sampling at the Exxon facility. Construction material for the controlled condensation system can be 316L stainless steel, which had the best performance when subjected to various tests used to simulate an FBC environment and will easily withstand the pressures found at the Exxon facility. |
Notes |
"Industrial Environmental Research Laboratory, Office of Energy, Minerals, and Industry, Research Triangle Park, N.C." "July 1979." "Contract no. 68-02-2613, task no. 3, program element no. INE624." Includes bibliographical references. |