Grantee Research Project Results
Design and Testing of a Point of Use Electrolytic Chlorine Generator for Drinking Water Disinfection in Poor Countries
EPA Grant Number: SU833521Title: Design and Testing of a Point of Use Electrolytic Chlorine Generator for Drinking Water Disinfection in Poor Countries
Investigators: Just, Craig
Current Investigators: Just, Craig , Tuttle, Robert D. , Meggo, Richard E. , Teed, Richard H. , Lozier, Matthew J. , Moriarty, Holly M. , Gwinnup, Aaron , Keenan, Alexandra , Smith, Jessica , Donham, Joel , Lamb, Jon , Schafer, Michael , Heacock, Nicole , Frystak, Phillip , Rhoads, Thomas
Institution: University of Iowa
EPA Project Officer: Page, Angela
Phase: I
Project Period: September 30, 2007 through May 30, 2008
Project Amount: $10,000
RFA: P3 Awards: A National Student Design Competition for Sustainability Focusing on People, Prosperity and the Planet (2007) RFA Text | Recipients Lists
Research Category: Drinking Water , P3 Challenge Area - Safe and Sustainable Water Resources , Pollution Prevention/Sustainable Development , P3 Awards , Sustainable and Healthy Communities
Objective:
This project will focus on the redesign, characterization and efficacy of a point of use electrolytic chlorine generator targeted for poor countries around the world for the purpose of disinfecting drinking water.
Approach:
The development of an effective hand-held chlorinator is the main goal, but larger scale, flow-through systems will also be considered. The chlorine species generated by all prototypes will be characterized using wet chemistry and analytical equipment readily available to the research group. Disinfection by-product formation potential will be determined for a variety of potential source waters before and after filtration and/or coagulation/flocculation pretreatment. We will work with established organizations in the United States and abroad with international water delivery missions for effective participatory design efforts with our partner country, Haiti. The project will culminate with the installation of an electrolytic chlorinator(s) in Haiti with subsequent feedback and design improvement suggestions from the local communities that utilize the intermediate technology.
Relevant Websites:
Phase 2 AbstractProgress and Final Reports:
P3 Phase II:
Design and Testing of a Point of Use Electrolytic Chlorine Generator for Drinking Water Disinfection in Poor CountriesThe perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Conclusions drawn by the principal investigators have not been reviewed by the Agency.