Version 1.25.0

Emission Factor Details

SCC 20300202
  Level 1 Internal Combustion Engines
  Level 2 Commercial/Institutional
  Level 3 Natural Gas
  Level 4 Turbine
POLLUTANT 1,3-Butadiene NEI 106990 CAS 106-99-0
  Primary Control       CHEMICAL REDUCTION

Emission Factor < 4.300E-7 Lb per MMBtu Fuel Input
Quality D    Emissions Factors Applicability

References EPA. 2000. Section 3.1, Stationary Gas Turbines for Electricity Generation. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency.
AP 42 Section Chapter 3   Section 3.1
Formula
Notes Compound was not detected. Emission factor is based on one-half of the detection limit. Emission factor based on an average natural gas heating value (HHV) of 1020 Btu/scf at 60 deg. F. To convert from (lb/MMBtu) to (lb/10^6 scf) multiply by 1020. Also, this emission factor may be converted to other natural gas heating values by multiplying the given emission factor by the ratio of the specified heating value to the average heating value of 1020 Btu/scf.