Science Inventory

Per- and polyfluoroalkyl ether acids in well water and blood serum from private well users residing by a fluorochemical facility near Fayetteville, North Carolina

Citation:

Kotlarz, N., T. Guillette, C. Critchley, D. Collier, S. Lea, J. McCord, M. Strynar, M. Cuffney, Z. Hopkins, D. Knappe, AND J. Hoppin. Per- and polyfluoroalkyl ether acids in well water and blood serum from private well users residing by a fluorochemical facility near Fayetteville, North Carolina. Journal of Exposure Science and Environmental Epidemiology . Nature Publishing Group, London, Uk, 34:97-107, (2024). https://doi.org/10.1038/s41370-023-00626-x

Impact/Purpose:

Since 1980, a fluorochemical facility near Fayetteville, North Carolina, emitted per- and polyfluoroalkyl ether acids (PFEAs), a subgroup of per- and polyfluoroalkyl substances (PFAS), to air and water. PFAS are a large class of synthetic, fluorinated chemicals. Fluorochemical facilities are important sources of environmental PFAS contamination. The fluorochemical industry is producing derivatives of perfluoroalkyl acids, including per- and polyfluoroalkyl ether acids (PFEAs). PFEAs have been detected in various environmental samples but there is not much information on PFEA-exposed populations. While serum biomonitoring is often used for PFAS exposure assessment, serum analysis had limitations for characterizing PFEA exposure. Environmental measurements and other approaches besides serum monitoring will be needed to characterize exposure to these compounds. Our objective was to analyze PFAS in private wells near the facility and in blood from well users to assess relationships between PFEA levels in well water and blood serum.

Description:

Background: A fluorochemical facility near Fayetteville, North Carolina, emitted per- and polyfluoroalkyl ether acids (PFEAs), a subgroup of per- and polyfluoroalkyl substances (PFAS), to air. Objective: Analyze PFAS in private wells near the facility and in blood from well users to assess relationships between PFEA levels in water and serum. Methods: In 2019, we recruited private well users into the GenX Exposure Study and collected well water and blood samples. We targeted 26 PFAS (11 PFEAs) in water and 27 PFAS (9 PFEAs) in serum using liquid chromatography-mass spectrometry. We used regression modeling to explore relationships between water and serum PFAS. For the only PFEA detected frequently in water and serum, Nafion byproduct 2, we used generalized estimating equation (GEE) models to assess well water exposure metrics and then adjusted for covariates that may influence Nafion byproduct 2 serum concentrations. Results: We enrolled 153 participants ages 6 and older (median = 56 years) using 84 private wells. Most wells (74%) had ≥6 detectable PFEAs; median ∑PFEAs was 842 ng/L (interquartile range = 197-1760 ng/L). Low molecular weight PFEAs (PMPA, HFPO-DA [GenX], PEPA, PFO2HxA) were frequently detected in well water, had the highest median concentrations, but were not detectable in serum. Nafion byproduct 2 was detected in 73% of wells (median = 14 ng/L) and 56% of serum samples (median = 0.2 ng/mL). Cumulative dose (well concentration × duration at address) was positively associated with Nafion byproduct 2 serum levels and explained the most variability (10%). In the adjusted model, cumulative dose was associated with higher Nafion byproduct 2 serum levels while time outside the home was associated with lower levels. Impact: PFAS are a large class of synthetic, fluorinated chemicals. Fluorochemical facilities are important sources of environmental PFAS contamination globally. The fluorochemical industry is producing derivatives of perfluoroalkyl acids, including per- and polyfluoroalkyl ether acids (PFEAs). PFEAs have been detected in various environmental samples but information on PFEA-exposed populations is limited. While serum biomonitoring is often used for PFAS exposure assessment, serum biomarkers were not good measures of long-term exposure to low molecular weight PFEAs in a private well community. Environmental measurements and other approaches besides serum monitoring will be needed to better characterize PFEA exposure.

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:01/10/2024
Record Last Revised:03/08/2024
OMB Category:Other
Record ID: 360643