You are here:
Design Manual: Removal of Fluoride from Drinking Water Supplies by Activated Alumina
Citation:
Chen, A. Design Manual: Removal of Fluoride from Drinking Water Supplies by Activated Alumina. U.S. EPA Office of Research and Development, Washington, DC, EPA/600/R-14/236, 2014.
Impact/Purpose:
Design Manual on removing fluoride from drinking water to support the fluoride MCL - manual
Description:
This document is an updated version of the Design Manual: Removal of Fluoride from Drinking Water Supplies by Activated Alumina (Rubel, 1984). The manual is an in-depth presentation of the steps required to design and operate a fluoride removal plant using activated alumina (AA), which is a reliable and cost-effective process for treating excess fluoride from drinking water supplies.
Record Details:
Record Type:DOCUMENT( PUBLISHED REPORT/ MANUAL)
Product Published Date:09/30/2014
Record Last Revised:10/29/2014
OMB Category:Other
Record ID:
291091