Science Inventory

Verification Results of Jet Resonance-enhanced Multiphoton Ionization as a Real-time PCDD/F Emission Monitor

Citation:

GULLETT, B. K., L. OUDEJANS, A. TOUATI, S. P. RYAN, AND D. G. TABOR. Verification Results of Jet Resonance-enhanced Multiphoton Ionization as a Real-time PCDD/F Emission Monitor . ISSN 1438-4957 , K. Yamamoto; S. Sakai (ed.), Journal of Material Cycles and Waste Management. Springer Japan KK, Tokyo, Japan, 10(1):32-37, (2008).

Impact/Purpose:

journal article

Description:

The Jet REMPI (Resonance Enhanced Multiphoton Ionization) monitor was tested on a hazardous waste firing boiler for its ability to determine concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI is a real time instrument capable of highly selective and sensitive (part per trillion to part per billion) detection of a broad range of aromatic compounds including a number of air toxic compounds. This limited testing shows that Jet REMPI has promise as an on-line diagnostic monitor, providing feedback on the effects of operating parameter changes, such as fuel feed interruptions or air pollution control ailures, on PCDD/F emissions.

Record Details:

Record Type:DOCUMENT( JOURNAL/ PEER REVIEWED JOURNAL)
Product Published Date:03/01/2008
Record Last Revised:05/29/2008
OMB Category:Other
Record ID: 166983