FINAL

RBLC ID: LA-0292
Corporate/Company: CAMERON INTERSTATE PIPELINE LLC
Facility Name: HOLBROOK COMPRESSOR STATION
Process: Waukesha 16V-275GL Compressor Engines Nos. 1-12

Pollutant: Particulate matter, total < 2.5 µ (TPM2.5) CAS Number: PM
 
Pollutant Group(s):  Particulate Matter (PM), Substance Registry System: Particulate matter, total < 2.5 µ (TPM2.5)
 
Pollution Prevention/Add-on Control Equipment/Both/No Controls Feasible: P
P2/Add-on Description: Use of natural gas as fuel, good equipment design, and proper combustion techniques

Test Method: Unspecified EPA/OAR methods are those found in EPA 40 CFR parts 51, 60, 61, or 63 or otherwise available on the EPA/TTN/EMC website. All other methods (e.g., ASTM, CARB, NCASI, and SW) can found through the appropriate link on the EMC Related Website Page.
   
Percent Efficiency: 0
Compliance Verified: Unknown
EMISSION LIMITS:
  Case-by-Case Basis: BACT-PSD
  Other Applicable Requirements: OPERATING PERMIT
  Other Factors Influence Decision: Unknown
  Emission Limit 1: 0.0030 LB/HR HOURLY MAXIMUM
  Emission Limit 2: 0.0100 TPY ANNUAL MAXIMUM
  Standard Emission Limit: 0
COST DATA:
  Cost Verified? No
  Dollar Year Used in Cost Estimates:
  Cost Effectiveness: 0 $/ton
  Incremental Cost Effectiveness: 0 $/ton
  Pollutant Notes: Compressor engines are also subject to a BACT limit of 0.0000771 lb/MM Btu.