Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 2 OF 23

OLS Field Name OLS Field Data
Main Title Calibration of a 90ê V-notch weir using parameters other than upstream head /
Author Eli, Robert. ; Pedersen, Harald ; Snyder, Ronald
Other Authors
Author Title of a Work
Pedersen, Harald.
Snyder, Ronald.
CORP Author West Virginia Univ., Morgantown. Dept. of Civil Engineering.;Environmental Monitoring and Support Lab., Cincinnati, OH.
Publisher Environmental Monitoring and Support Laboratory, Office of Research and Development, U.S. Environmental Protection Agency ; National Technical Information Service [distributor],
Year Published 1980
Report Number EPA 600-4-80-035; EPA-R-805312-01-1
Stock Number PB80-226269
OCLC Number 07199111
Subjects Weirs. ; Water-meters--Calibration. ; Water quality management--United States.
Additional Subjects Weirs ; Flow measurement ; Flow rate ; Open channel flow ; Statistical data
Internet Access
Description Access URL
http://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101ENHT.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJAD  EPA 600/4-80-035 Region 3 Library/Philadelphia, PA 02/16/1996
EJBD ARCHIVE EPA-600-4-80-035 Headquarters Library/Washington,DC 04/14/2014
EJED  EPA 600-4-80-035 OCSPP Chemical Library/Washington,DC 06/04/2019
EKAM  TD178.6.E62 600 1980, no.035 Region 4 Library/Atlanta,GA 06/24/1994
ESAD  EPA 600-4-80-035 Region 10 Library/Seattle,WA 04/22/2005
NTIS  PB80-226269 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation ix, 110 pages : illustrations ; 28 cm.
Abstract Traditional calibration of 90 degrees V-Notch Weirs has involved the establishment of a head-discharge relationship where the head is measured upstream of weir drawdown effects. This parameter is often difficult to mesure in field weir installations. Two other parameters are proposed for use as correlation parameters to weir discharge. These parameters are depth and width of flow at the weir notch. Techniques for measuring these parameters are proposed that result in less than 10% error in discharge at the 95% probability level in the laboratory environment.
Notes "Department of Civil Engineering, West Virginia University." "Project Management Section, Environmental Monitoring and Support Laboratory." "EPA 600-4-80-035." "July 1980." Cover title. Includes bibliographical references. "R805312-01-1."
Place Published Cincinnati, Ohio Springfield, Va.
Corporate Au Added Ent United States. Environmental Protection Agency. Office of Research and Development.; Environmental Monitoring and Support Laboratory (Cincinnati, Ohio). Project Management Section.; West Virginia University. Department of Civil Engineering.
Title Ser Add Ent Research reporting series. Environmental monitoring ; EPA-600/4-80-035.
PUB Date Free Form 1980
Series Title Traced Research reporting series Environmental monitoring ; EPA-600/4-80-035
Series Title Untraced Research reporting series. 4, Environmental monitoring ; EPA-600/4-80-035
NTIS Prices PC A06/MF A01
BIB Level m
Medium unmediated
Content text
Carrier volume
Cataloging Source OCLC/T
Merged OCLC records 83589771
OCLC Time Stamp 20190531061452
Language eng
SUDOCS Number EP 1.23/5:600/4-80-035
Origin OCLC
Type MERGE
OCLC Rec Leader 03124cam 2200649Ia 45010