Main Title |
Development of multipollutant emission control technology for stoker boilers / |
Author |
Sedman, Charles B.
|
Other Authors |
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Publisher |
U.S. Environmental Protection Agency, National Risk Management Research Laboratory, Air Pollution Prevention and Control, |
Year Published |
1998 |
Report Number |
EPA/600/A-99/005 |
Stock Number |
PB99-129819 |
Additional Subjects |
Coal fired boilers ;
Stokers ;
Air pollution control equipment ;
Emission control ;
Removal ;
Sorbents ;
Filtration ;
Electrostatic precipitators ;
Combustion products ;
Particulates ;
Particles ;
Nitrogen oxides ;
New Source Performance Standards
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB99-129819 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
20 pages ; 28 cm |
Abstract |
The paper discusses the development of multipollutant emission control technology for stoker boilers. Effort to develop a compact multipollutant control system for coal-fired boilers include: (1) particle removal combining electrostatics and fabric filtration, (2) combined acid gas and metal vapor control using a compact, verticle-pipe reactor with new lime-based sorbents, and (3) promoted oxidation and absorpton of nitrogen oxides (NOx). An array of government and private partnerships have been formed to develop such a process step independentlly. Plans to combine process steps include a number of field pilot evaluations, followed by a 200 MBtu/hr (60 MWt) stoker demonstration in Ohio. |
Notes |
"EPA/600/A-99/005." Microfiche. |
Place Published |
Research Triangle Park, NC : |
Supplementary Notes |
Presented at the Stoker Boiler Workshop, Dayton, OH., August 19-20, 1998. See also PB82-115312 and PB89-194039. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Corporate Au Added Ent |
Air Pollution Prevention and Control. ; United States. |
PUB Date Free Form |
{1998} |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20000630165035 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01085nam 2200253Ka 45020 |