Main Title Evaluation of particulate matter (PM) continuous emission monitoring systems (CEMS) : final report, volume 5 - appendix H.
Author Bivins, D.
Other Authors
Author Title of a Work
Bivens, Dan.
CORP Author Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Publisher U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, Emissions Monitoring and Analysis Division, Emissions Measurement Center,
Year Published 2000
Report Number EPA/454/R-00/040e
Stock Number PB2001-102600
OCLC Number 48062853
Subjects Continuous emission monitoring. ; Air--Pollution--Measurement.
Additional Subjects Air pollution monitoring ; Particulates ; Boilers ; Flue gas ; Scrubbers ; Quality assurance ; Emissions ; Air pollution monitors ; Air pollution sampling ; Air pollution control ; CEMS(Continuous Emission Monitoring Systems) ; Continuous Emission Monitoring Systems
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2001-102600 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 01/01/1988
Collation 200 pages : illustrations, charts, facsimiles, plans ; 28 cm
Abstract This final report describes an extended field demonstration of three particulate matter (PM) continuous emission monitoring systems (CEMS) at a coal-fired boiler equipped with a lime slurry scrubber and baghouse for air pollution control. The primary objectives of the field study were to: (1) demonstrate whether the PM CEMS could provide reliable and accurate data over an extended period, (2) evaluate whether the PM CEMS satisfy all the requirements of draft-PS-11 and the quality assurance (QA) criteria specified in draft Procedure 2, or determine if changes are needed in the requirements of PS-11 and/or Procedure 2. This report presents the results of the study involving two different PM CEMS technologies (light scatter and beta gauge) at the coal-fired boiler.
Notes "Volume 5 of 5 volumes." Cover title. EPA Project Officer: Dan Bivens. Prepared by Midwest Research Institute (MRI) for the U.S. Environmental Protection Agency. "September 2000." Final report. "MRI Project no. 104703.1.002.07.01"--Page [i] v.1. Microfiche.
Contents Notes v. 1. Technical report -- v. 2. Appendices for initial correlation tests -- v. 3. Appendices for RCA no. 1 -- v. 4. Appendices for RCA no. 2 -- v. 5 Appendix H.
Place Published Research Triangle Park, N.C. :
Supplementary Notes See also PB2001-102596, PB2001-102597, PB2001-102598 and PB2001-102599.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Corporate Au Added Ent Emissions Measurment Center (U.S.) ; United States. Environmental Protection Agency. Emissions Monitoring and Analysis Division. ; Midwest Research Institute (Kansas City, Mo.)
PUB Date Free Form {2000}.
NTIS Prices PC A10/MF A03
BIB Level m
Cataloging Source OCLC/T
OCLC Time Stamp 20011001175310
Language eng
Origin OCLC
Type MERGE
OCLC Rec Leader 01801nam 2200361Ka 45020