Main Title |
Optimization of Purging Efficiency and Quantification of Organic Contaminants from Water Using a 1-L Closed-Loop-Stripping Apparatus and Computerized Capillary Column GC/MS. |
Author |
Coleman, W. E. ;
Munch, J. W. ;
Slater, R. W. ;
Melton, R. G. ;
Kopfler, F. C. ;
|
CORP Author |
Health Effects Research Lab., Cincinnati, OH. |
Year Published |
1983 |
Report Number |
EPA/600/J-82/037; |
Stock Number |
PB84-244128 |
Additional Subjects |
Chemical analysis ;
Water analysis ;
Chlorine organic compounds ;
Traps ;
Design criteria ;
Performance evaluation ;
Gas chromatography ;
Mass spectroscopy ;
Purging ;
Ground water ;
Potable water ;
Reprints ;
Closed loop stripping systems ;
Water pollution detection ;
Computer applications
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB84-244128 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
8p |
Abstract |
Optimization of a HERL-designed 1-L closed-loop-stripping (CLS) system, using variations of sample water bath temperatures and purging times, was accomplished by spiking five 1-chloroalkanes (C6, C8, C12, C16, and C18) into low organic Milli-Q reagent water to determine the recovery efficiency of each. Once operating conditions of purging time and water bath temperature were determined, on the basis of optimum recovery of the 1-chloroalkanes, recovery studies of a 22-compound standard mixture of organics were initiated by using two 1-L CLS devices of different design. This report supports previous CLS applications papers (2-4) demonstrating that CLS-capillary column GC/MS is an excellent method to measure many toxic organics in drinking water and in groundwater. For quantitative results, recovery efficiencies of individual compounds must be determined in the same matrix as the sample matrix. |
Supplementary Notes |
Pub. in Environmental Science Technology, v17 n10 p571-576 1983. |
NTIS Title Notes |
Journal article. |
Title Annotations |
Reprint: Optimization of Purging Efficiency and Quantification of Organic Contaminants from Water Using a 1-L Closed-Loop-Stripping Apparatus and Computerized Capillary Column GC/MS. |
PUB Date Free Form |
1983 |
Category Codes |
7D; 14B; 99A; 68D |
NTIS Prices |
PC A02/MF A01 |
Primary Description |
600/11 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
435625628 |
Origin |
NTIS |
Type |
CAT |