Main Title |
Physical - Chemical Treatment Plant Design. |
Author |
Culp., Gordon L. ;
|
CORP Author |
CH2M-Hill, Reston, Va.;Environmental Protection Agency, Washington, D.C. |
Year Published |
1972 |
Stock Number |
PB-256 957 |
Additional Subjects |
Sewage treatment ;
Design criteria ;
Process charting ;
Chemical removal(Sewage treatment) ;
Phosphorus ;
Coagulants ;
Adsorbents ;
Flocculation ;
Carbon ;
Physical chemical sewage treatment
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB-256 957 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
34p |
Abstract |
The various approaches to physical-chemical treatment all involve the use of coagulation and settling for removal of suspended solids and, in some cases, phosphorus. Also, all involve the use of activated carbon for the removal of soluble organics. Some also involve the use of filtration for further removals of suspended solids and phosphorus. The purpose of this paper is to discuss typical design parameters for the unit processes involved in physical-chemical treatment of raw wastes and how the design engineer may determine the design criteria best suited for a given wastewater. |
Supplementary Notes |
Prepared for Environmental Protection Agency, Washington, D.C. |
PUB Date Free Form |
Aug 72 |
Category Codes |
13B; 68D |
NTIS Prices |
PC A03/MF A01 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |