Main Title |
Biomass power plant demonstration at Camp Lejeune / |
Author |
Schmidt, D. D. ;
Purvis, C. R. ;
Cleland, J. G.
|
Other Authors |
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Publisher |
U.S. Environmental Protection Agency, Air Pollution Prevention and Control Division, |
Year Published |
1998 |
Report Number |
EPA/600/A-98/141; EPA-R-822871 |
Stock Number |
PB99-126476 |
Subjects |
Air--Pollution
|
Additional Subjects |
Electric power plants ;
Biomass conversion plants ;
Marine Corps facilities ;
Air pollution abatement ;
Refuse fueled power plant ;
Electric power generation ;
Biomass energy production ;
Spark ignition engines ;
Refuse derived fuels ;
Wood ;
Tars ;
Drying ;
Combustion ;
Gasification ;
Activated carbon treatment ;
Camp Lejeune Military Reservation ;
Gas cleaning
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB99-126476 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
10 pages ; 28 cm |
Abstract |
The paper discusses a biomass power plant at Camp Lejeune, undertaken to demonstrate that biomass energy conversion is a competitive lower-polluting, electrical power option for government installations, industrial sites, rural cooperatives, small municipalities, and regions of developing countries. The plant incorporates a moving bed bulk wood dryer; a downdraft, fixed-bed gasifier utilizing hogged wood residues; a gas cleaning and cooling system; and a spark ignition engine. Operation of the plant has resulted in characterization of all major technical challenges and provided solutions. The paper briefly describes the process design, initial operational results, and further needs. |
Notes |
Microfiche. |
Place Published |
Research Triangle Park, NC : |
Supplementary Notes |
Presented at Bioenergy '98, Madison, WI., October 4-8, 1998. See also PB98-135676. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Corporate Au Added Ent |
United States. ; Air Pollution Prevention and Control Division. |
PUB Date Free Form |
1998. |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20000627144949 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01002nam 2200265Ka 45020 |