Main Title |
An evaluation of the E-SOx process on the EPA pilot electrostatic precipitator / |
Author |
Hovis, Louis S.
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Office of Research and Development, Air and Energy Engineering Research Laboratory, |
Year Published |
1990 |
Report Number |
EPA/600/7-90/011 |
Stock Number |
PB90-216441 |
Subjects |
Boilers--Fuel--Environmental aspects--United States ;
Electrostatic precipitation ;
Sulfur dioxide ;
Sulphur dioxide
|
Additional Subjects |
Air pollution control equipment ;
Electrostatic precipitators ;
Sulfur dioxide ;
Particles ;
Combustion products ;
Pilot plants ;
Spray drying ;
Performance evaluation ;
Sorbents ;
Electrodes ;
Temperature control ;
E-SOx process ;
Coal fired power plants ;
Retrofitting
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB90-216441 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
59 pages : illustrations ; 28 cm |
Abstract |
The report gives results of a small pilot-scale evaluation of the E-SOx process, undertaken to obtain information needed to conduct a planned 5 MWe field pilot demonstration. The process uses an electrostatic precipitator (ESP) for combined sulfur dioxide (SO2) removal and particulate collection. The concept of spray drying is introduced to the inlet and/or first section of the ESP in which electrical components are removed. Because of the many ESPs at coal-fired power plants, the process is well suited to retrofitting. Evaluation results indicate that a 50-60% SO2 removal at a calcium/sulfur ratio of 1.2-1.4 can be obtained. Furthermore, this SO2 reduction can be achieved without degrading the particulate emissions event though the process requires a reduction in the collecting surface of the ESP. The use of a temperature-controlled electrode precharger to compensate for collecting surface loss is also described. |
Notes |
Caption title. "May 1990." "EPA/600/7-90/011." Microfiche. |
Place Published |
Research Triangle Park, NC : |
Corporate Au Added Ent |
United States. Environmental Protection Agency. Office of Research and Development. ; Air and Energy Engineering Research Laboratory. |
PUB Date Free Form |
{1990} |
NTIS Prices |
PC A04/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20001121134142 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
01257nam 2200301Ka 45020 |