Main Title |
Evaluation of aronetics two-phase jet scrubber / |
Author |
McCain, Joseph D.
|
CORP Author |
Southern Research Inst., Birmingham, Ala.;National Environmental Research Center, Research Triangle Park, N.C. Control Systems Lab. |
Publisher |
Office of Research and Development, U.S. Environmental Protection Agency ; Available to the public through the National Technical Information Service, |
Year Published |
1974 |
Report Number |
PB-239 422; EPA/650-2-74-129; SORI-EAS-75-022; EPA-68-02-1480; EPA-ROAP-21ADL-004 |
Stock Number |
PB-239 422 |
OCLC Number |
53278800 |
Subjects |
Furnaces, Electric-arc--Environmental aspects ;
Scrubber (Chemical technology)
|
Additional Subjects |
Scrubbers ;
Particles ;
Air pollution control equipment ;
Flue gases ;
Performance evaluation ;
Particle size ;
Metallurgical furnaces
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 650-2-74-129 |
|
Headquarters Library/Washington,DC |
06/27/2014 |
EKBD |
EPA-650/2-74-129 |
|
Research Triangle Park Library/RTP, NC |
11/16/2016 |
ELBD ARCHIVE |
EPA 650-2-74-129 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
NTIS |
PB-239 422 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xi, 37 pages : illustrations, charts ; 28 cm. |
Abstract |
The report gives results of fractional and overall mass efficiency tests of the Aronetics two-phase jet scrubber. The tests were performed on a full scale scrubber used for controlling particulate emissions from a ferroalloy electric arc furnace. Total flue gas particulate mass concentrations were determined at the inlet and outlet of the scrubber by conventional (Method 5) techniques. Inlet and outlet particulate concentrations as functions of size were determined on a mass basis using cascade impactors for sizes of about 0.3-5 micrometers, and on a number basis for sizes smaller than about 1 micrometer using optical and diffusional methods. The report includes brief descriptions of the ferroalloy furnace process, the Aronetics scrubber, economics of operating the scrubber, measurement methods for determining fractional efficiency, a time history of the furnace particulate emissions, and measured fractional efficiencies. |
Notes |
"EPA/650-2-74-129." "December 1974." |
Place Published |
Research Triangle Park Springfield, Va. |
Corporate Au Added Ent |
Southern Research Institute.; United States. Environmental Protection Agency. Office of Research and Development. |
Title Ser Add Ent |
Research reporting series. Environmental protection technology ; EPA-650/2-74-129. |
PUB Date Free Form |
1974 |
Series Title Traced |
Research reporting series Environmental protection technology ; EPA-650/2-74-129 |
Series Title Untraced |
Research reporting series. Environmental protection technology ; EPA-650/2-74-129 |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Medium |
unmediated |
Content |
text |
Carrier |
volume |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20161104064833 |
Language |
eng |
Origin |
OCLC |
Type |
MERGE |
OCLC Rec Leader |
01827cam 2200421Ka 45010 |