Main Title |
The use of a Fourier transform spectrometer as a remote sensing sensor at Superfund sites. / |
Author |
Russwurm, G. M. ;
Kagann, R. H. ;
Simpson, O. A. ;
McClenny., W. A.
|
CORP Author |
Northrop Services, Inc., Research Triangle Park, NC. ;MDA Scientific, Inc., Norcross, GA. ;ManTech Environmental Technology, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Atmospheric Research and Exposure Assessment Lab. |
Publisher |
US Environmental Protection Agency, Atmospheric Research and Exposure Assessment Laboratory, |
Year Published |
1991 |
Report Number |
EPA-68-02-4444; EPA-68-DO-0106; EPA/600/D-91/115 |
Stock Number |
PB91-199844 |
Subjects |
Optics ;
Remote sensing ;
Fournier transform spectrometer
|
Additional Subjects |
Air pollution detection ;
Remote sensing ;
Superfund ;
Waste disposal ;
Fourier transform spectrometers ;
Site surveys ;
Infrared spectroscopy ;
Performance evaluation ;
Design criteria ;
Concentration(Composition) ;
Quality assurance ;
Northwest Region(Georgia)
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB91-199844 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
15 pages ; 29 cm |
Abstract |
A Fourier transform infrared remote sensor (FTIR-RS) was used to measure chemical emissions at the Shaver's Farm Superfund site in northwestern Georgia. The system was bistatic with a source/receiver at one end of a 250 m path and a retroreflector at the other end. The source/receiver was a Nicolet Model 730 FTIR system coupled to a telescope with the appropriate transfer optics. The average concentrations of target gases along the path are inferred by matching field spectra with reference spectra of precisely measured quantities of the target gases. Measurements indicated that benzonitrile and benzaldehyde concentrations at the site were lower than the FTIR-RS detection limits of 70 and 16 ppm-m, respectively. Background IR radiation was successfully eliminated by modulating the IR beam before it was transmitted along the path. Quality assurance measurements to establish the precision and accuracy of known gas burdens (ppm-m) were carried out using a 15-cm cell containing high concentrations of several gases. |
Notes |
"EPA 600/D-91/115." Microfiche. |
Place Published |
Research Triangle Park, NC.,: |
Supplementary Notes |
Prepared in cooperation with MDA Scientific, Inc., Norcross, GA., and ManTech Environmental Technology, Inc., Research Triangle Park, NC. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Atmospheric Research and Exposure Assessment Lab. |
PUB Date Free Form |
1991. |
NTIS Prices |
PC A03/MF A01 |
BIB Level |
m |
Cataloging Source |
OCLC/T |
OCLC Time Stamp |
20010118144555 |
Language |
eng |
Origin |
NTIS |
Type |
MERGE |
OCLC Rec Leader |
00940nam 2200241Ka 45020 |