Main Title |
Ion Abundance Criteria for Gas Chromatographic/Mass Spectrometric Environmental Analysis. |
Author |
Donnelly, J. R. ;
Sovocool, G. W. ;
Mitchum, R. K. ;
|
CORP Author |
Lockheed-EMSCO, Las Vegas, NV.;Environmental Monitoring Systems Lab., Las Vegas, NV. |
Year Published |
1988 |
Report Number |
EPA-68-03-3249; EPA/600/J-88/055; |
Stock Number |
PB88-250790 |
Additional Subjects |
Environmental tests ;
Calibrating ;
Standards ;
Gas chromatography ;
Mass spectroscopy ;
Accuracy ;
Quality assurance ;
Quantitative analysis ;
Reproducibility ;
Phosphines ;
Chemical analysis ;
Reprints ;
Ion abundance ;
Decafluorotriphenyl phosphine
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB88-250790 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
8p |
Abstract |
Mass and intensity calibration of gas chromatograph/mass spectrometer (GC/MS) responses is an important quality assurance issue for chemical analysis. Ion abundance calibration with decafluorotriphenylphosphine (DFTPP) was applied in 1975 to standardize quadrupole spectra to resemble the ion abundances that were obtainable from magnetic sector mass spectrometers. Modern quadrupole mass spectrometers provide significantly greater high-mass sensitivity than allowed under the 1975 study. Thus, those recommendations were reevaluated with two approaches. First, an interlaboratory study was conducted using 15 different gas chromatography/mass spectrometry (GC/MS) systems. Second, the U.S. Environmental Protection Agency Contract Laboratory Program (EPA-CLP) quality assurance data base was searched and over 6500 DFTPP tune results were plotted and evaluated. Based on these approaches, updated ion abundance criteria recommendations have been developed, which contemporary instruments can meet, and which meet data quality objectives regarding identification and quantitative analysis of analytes. |
Supplementary Notes |
Pub. in Jnl. of the Association of Official Analytical Chemists, v71 n2 p434-439 1988. Sponsored by Environmental Monitoring Systems Lab., Las Vegas, NV. |
NTIS Title Notes |
Journal article. |
Title Annotations |
Reprint: Ion Abundance Criteria for Gas Chromatographic/Mass Spectrometric Environmental Analysis. |
PUB Date Free Form |
c1988 |
Category Codes |
99A; 68A; 68D; 94K |
NTIS Prices |
PC A02/MF A01 |
Primary Description |
600/07 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
831528001 |
Origin |
NTIS |
Type |
CAT |