Main Title |
Iron and Steel Foundaries Manual Emissions Testing of Cupola Baghouse at Waupaca Foundry in Tell City, Indiana. Volume 1 of 2. Report Text and Appendices A and B. |
Author |
Meadows, F. ;
Scheffel, D. F. ;
|
CORP Author |
Pacific Environmental Services, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards. |
Publisher |
Jun 1999 |
Year Published |
1999 |
Report Number |
EPA-68-D-70069; EPA/454/R-99/017A; |
Stock Number |
PB99-163453 |
Additional Subjects |
Iron and steel industry ;
Foundries ;
Air pollution sampling ;
Exhaust gases ;
Particulates ;
Dioxins ;
Furans ;
Metals ;
Stack gases ;
Cupolas ;
Baghouses ;
Foundary practice ;
Air pollution control equipment ;
Analytical methods ;
Measurement ;
Data acquisition ;
Data analysis ;
Quality assurance ;
Quality control ;
Tell City(Indiana) ;
Perry County(Indiana) ;
Semivolatile organic compounds ;
Hazardous air pollutants ;
EMAD(Emissions Monitoring and Analysis Division)
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB99-163453 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
594p |
Abstract |
The U.S. Environmental Protection Agency (EPA) Emission Standards Division (ESD) is investigating iron and steel foundries to identify and quantify hazardous air pollutants (HAPs) emitted from cupolas; electric arc furnaces; and pouring, cooling and shakedown operations of sand mold casting processes. The Waupaca Foundry, located in Tell City, Indiana, uses a baghouse and was the subject of this test program. Testing at the Waupaca Foundry was conducted by two EMAD contractors to address the following ESD requirements: (1) characterize HAP emissions from cuplas that are controlled by baghouses; (2) characterize uncontrolled HAP emissions from pouring, cooling, and shakeout (PCS) processes; (3) determine baghouse performance in controlling HAP emissions from cupolas; and (4) identify surrogates for estimating HAP emissions from the subject foundary processes. |
Supplementary Notes |
See also Volume 2, PB99-163461. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
NTIS Title Notes |
Final rept. |
Category Codes |
68A; 41E; 94G |
NTIS Prices |
PC A99/MF A06 |
Primary Description |
200/04 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
930200700 |
Origin |
NTIS |
Type |
CAT |