Main Title |
Effect of Relative Humidity on Gaseous Air Cleaner Media Performance: Toluene Adsorption by Activated Carbon. |
Author |
Owen, M. K. ;
VanOsdell, D. W. ;
Jaffe, L. B. ;
Sparks, L. E. ;
|
CORP Author |
Research Triangle Inst., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Publisher |
1998 |
Year Published |
1998 |
Report Number |
EPA-R-822870-01; EPA/600/A-98/096; |
Stock Number |
PB98-151772 |
Additional Subjects |
Toluene ;
Adsorption ;
Activated carbon treatment ;
Emissions ;
Air pollution control equipment ;
Air cleaners ;
Gases ;
Granular activated filters ;
Test chambers ;
Flow rates ;
Air flow ;
Ecological concentration ;
Relative humidity ;
Performance evaluation ;
Indoor air pollution ;
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB98-151772 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
18p |
Abstract |
The paper gives results of an examination of the performance characteristics of activated carbon as a gas-phase air cleaner medium under various levels of relative humidity (RH) and a range of toluene concentrations. Toluene breakthrough curves at levels of humidity from below 5 to 80% were obtained. The concentration of the toluene challenge varied from 0.4 to 72.8 ppm. The experiments were performed in a small-scale test rig with temperature, flowrate, and humidity controls. These experiments provided data to explore the relationship of useful lifetime to RH. Below 50% RH, RH appears to have negligible influence on the adsorption of toluene but, by 75% RH, the toluene adsorption is decreased. Above the inflection point in the relationship between the cabon water content and the RH of the challenge air, the water interferes with the adsorption of toluene. Thus, the water adsorption curve supports the toluene adsorption data. The lineaarity of the relationship between the concentration and the 10% breakthrough time indicates that high concentration breakthrough data can be used to predict the breakthrough time for lower concentration challenges. |
Supplementary Notes |
Presented at EPA/AWMA Conference, 'Engineering Solutions to Indoor Air Quality Problems', Research Triangle Park, NC., July 24-26, 1995. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div. |
Availability Notes |
Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.fedworld.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
Category Codes |
68A; 89B |
NTIS Prices |
PC A03/MF A01 |
Primary Description |
600/13 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
830200740 |
Origin |
NTIS |
Type |
CAT |