Full Record Display for the EPA National Library Catalog

RECORD NUMBER: 25 OF 146

OLS Field Name OLS Field Data
Main Title Economic Impact Analysis of the Proposed Hospital Sterilizers Area Source Standard.
CORP Author Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Publisher Nov 2006
Year Published 2006
Report Number EPA/452/D-06/001;
Stock Number PB2007-101987
Additional Subjects Hospitals ; Sterilizers ; Economic impact analysis ; Air pollution control equipment ; Ethylene oxide ; Emissions ; Costs ; Area source standard ;
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2007-101987 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. NTIS 05/28/2007
Collation 13p
Abstract The portions of the hospital industry that are affected by this proposal are NAICS 62211 (General Medical and Surgical Hospitals) and NAICS 62231 (Specialty (Except Psychiatric and Substance Abuse) Hospitals). This category potentially includes many types of hospitals such as academic medical center/university-based/teaching hospitals, community hospitals, specialty hospitals (i.e., orthopedic or pediatric), and tertiary care facilities that are qualified to handle major trauma cases (i.e., burns and catastrophic accidents). There are also distinctions between public and private hospitals, hospitals that are part of a healthcare system (i.e., organizations such as Kaiser Permanente), Veterans Administration hospitals, and other types of facilities. The predominant type of air pollution control devices are the EtO-Abator (TM) and the Safe-Cell technology. Both technologies reduce emissions by approximately 99 percent. The EtO-AbatorTM oxidizes the EO with a catalyst to form CO2 and water vapor. The latest version of the EtO-Abator (TM) (sold by 3M) is sold only for use with pure EO systems; however, earlier versions were used with gas blends. The Safe-Cell technology, which can be used with either pure EO or EO gas blends, is a two-stage process. In the first stage, an acid hydrolysis scrubber removes EO from the gas stream and converts it to ethylene glycol (EG); in the second stage, the remaining EO is captured and destroyed on a dry bed filter impregnated with a chemical reactant.
Availability Notes Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA.
Category Codes 44H; 44Q; 68A
NTIS Prices PC A03/MF A01
Document Type NT
Cataloging Source NTIS/MT
Control Number 005100700
Origin NTIS
Type CAT