Main Title |
Testing the Performance of Real-Time Incinerator Emission Monitors. |
Author |
Ghorishi, S. B. ;
Whitworth, W. E. ;
Goldman, C. G. ;
Waterland, L. R. ;
|
CORP Author |
Acurex Corp., Jefferson, AR. Incineration Research Facility.;National Risk Management Research Lab., Cincinnati, OH. |
Publisher |
Mar 97 |
Year Published |
1997 |
Report Number |
EPA-68-C4-0044; EPA/600/R-97/024; |
Stock Number |
PB97-142871 |
Additional Subjects |
Incinerators ;
Air pollution monitors ;
Performance tests ;
Air pollution sampling ;
Flame ionization ;
Gas chromatography ;
Mass spectroscopy ;
Atomic absorption spectroscopy ;
Chemical analysis ;
Analytical methods ;
Quality assurance ;
Rotary kilns ;
Combustion products ;
Trace amounts ;
Metals ;
Mercury(Metal) ;
Polycyclic aromatic hydrocarbons ;
Flue gases ;
Emissions ;
Concentration(Composition) ;
Combustion efficiency ;
Accuracy ;
Continuous emission monitors ;
Inductively coupled argon plasma spectroscopy ;
Volatile organic compounds ;
Semivolatile organic compounds
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB97-142871 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
194p |
Abstract |
Ten prototypes of continuous emission monitors (CEMs) for measuring trace metal or trace organic species concentrations were tested. Of the 10 CEMs tested, four measured incinerator flue gas concentrations of several specific volatile organic compounds (VOCs), one measured total particulate-bound polynuclear aromatic hydrocarbon (PAH) concentrations, two measured flue gas concentrations of several (up to 14) trace metals, and three measured mercury concentrations. While the testing consisted of obtaining quantitative measurement data on the four measures of CEM performance checked in a relative accuracy test audit (RATA) as described in 40 CFR 60 Appendix F -- relative accuracy (RA), calibration drift (CD), zero drift (ZD), and response time - the primary project objective focused on the RA measurement. Four series of tests were performed, each simultaneously testing up to three monitors measuring the same or similar analyte type. Each test series consisted of performing triplicate Reference Method (RM) measurements at each of three target flue gas monitored analyte concentrations while the tested CEMs were in operation. |
Supplementary Notes |
Sponsored by National Risk Management Research Lab., Cincinnati, OH. |
Availability Notes |
This product may be ordered from NTIS by phone at (703)487-4650; by fax at (703)321-8547; and by email at 'orders@ntis.fedworld.gov'. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
NTIS Title Notes |
Project rept. |
Category Codes |
68A; 81A; 99F; 99B |
NTIS Prices |
PC A10/MF A03 |
Primary Description |
600/14 |
Document Type |
NT |
Cataloging Source |
NTIS/MT |
Control Number |
712601850 |
Origin |
NTIS |
Type |
CAT |