Main Title |
Sampling and Analysis of Asbestos Fibers on Filter Media to Support Exposure Assessment: Bench-Scale Testing. |
Author |
D. A. Vallero ;
J. R. Kominsky ;
M. E. Beard ;
O. Crankshaw
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. National Exposure Research Lab.; Environmental Quality Management, Inc., Cincinnati, OH.; RTI International, Research Triangle Park, NC.; Environmental Protection Agency, Research Triangle Park, NC. Office of Research and Development. |
Year Published |
2008 |
Report Number |
EPA/600/R-08/046; EPA-68-C-00-186; NERL-RTP-HEASD-08-017 |
Stock Number |
PB2009-102750 |
Additional Subjects |
Abestos fibers ;
Filter media ;
Sampling ;
Analysis ;
Exposure assessment ;
Bench-scale testing ;
April 2/06 - December 24/06
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB2009-102750 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
50p |
Abstract |
Sampling efficiency is essential in exposure assessments of contaminants in air, as well as other matrices. In the measurement of airborne contaminants, it is critical to collect a sample of air containing representative contaminants in the air of concern, that is, contaminant concentration and size distribution in the sampled air must be the same as that of the air of concern. Typically, mixed cellulose ester (MCE, 0.45 or 0.8 um pore size) and to a much lesser extent, capillary-pore polycarbonate (PC, 0.4 um pore size) membrane filters are used to collect airborne asbestos for count measurement and fiber size analysis. A literature review did not identify any study that compared the fiber retention efficiencies of 0.45 um and 0.8 um pore size MCE or 0.4 um pore size PC membrane filters for asbestos aerosols. In this research study chrysotile asbestos (fibers both shorter and longer than 5 um) were generated in an aerosol chamber and sampled by 25-mm diameter MCE filter media to compare the efficiency of a 0.45 um pore size filters versus 0.8 u pore size filter media. In addition, the effect of plasma etching times on fiber densities was evaluated. |
Supplementary Notes |
See also PB90-274283. This is a revision of report dated April 6, 2008. Prepared in cooperation with Environmental Quality Management, Inc., Cincinnati, OH. and RTI International, Research Triangle Park, NC. Sponsored by Environmental Protection Agency, Research Triangle Park, NC. Office of Research and Development. |
Availability Notes |
Also available on CD-ROM. Product reproduced from digital image. Order this product from NTIS by: phone at 1-800-553-NTIS (U.S. customers); (703)605-6000 (other countries); fax at (703)605-6900; and email at orders@ntis.gov. NTIS is located at 5285 Port Royal Road, Springfield, VA, 22161, USA. |
PUB Date Free Form |
5 Nov 2008 |
Category Codes |
71I; 68; 70E |
NTIS Prices |
PC A04/MF A04 |
Document Type |
NT |
Medium |
Report covering period 28 Apr |
Cataloging Source |
NTIS/MT |
Control Number |
010501810 |
Origin |
NTIS |
Type |
CAT |